Cooling Liquid Products RH-PCL-15

    • Product Name: Cooling Liquid Products RH-PCL-15
    • Factroy Site: No. 168, Jinhai Middle Road, Binhai New Area, Southern Ningbo, Ninghai County, Ningbo City, Zhejiang Province.
    • Price Inquiry: sales8@bouling-chem.com
    • Manufacturer: Zhejiang Runhe Chemical New Material Co., Ltd.
    • CONTACT NOW
    VTB
    Specifications
    HS Code 801204
    Product Name Cooling Liquid Products RH-PCL-15
    Manufacturer Cooling Liquid Products
    Manufacturer Part Number RH-PCL-15
    Product Category Cooling liquid
    Product Type Propylene glycol-based coolant
    Container Size 15 gal
    Container Type Drum
    Physical Form Liquid
    Color Pink
    Odor Mild
    Freeze Point -34 °F typical
    Boiling Point 265 °F typical
    Ph 9.0 to 10.5 typical
    Specific Gravity 1.05 typical
    Intended Application Cooling systems

    As an accredited Cooling Liquid Products RH-PCL-15 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Cooling Liquid Products RH-PCL-15 is packaged in a 15-liter high-density polyethylene container with secure screw cap for safe handling and storage.
    Container Loading (20′ FCL) Cooling Liquid Products RH-PCL-15 is loaded into a 20-foot FCL container, securely stowed, sealed, and prepared for shipment.
    Shipping Ship Cooling Liquid Products RH-PCL-15 in original, sealed containers according to its SDS and applicable transport rules. Verify UN number, hazard class, packing group, and labeling before dispatch; provide SDS and shipping papers. Protect from freezing, leakage, and incompatible materials; use qualified carriers.
    Storage Store RH-PCL-15 in a cool, dry, well-ventilated area away from heat, sparks, flames, and direct sunlight. Keep containers tightly closed, upright, clearly labeled, and protected from physical damage. Use secondary containment to control leaks. Separate from incompatible materials and oxidizers, and do not store near food or drink. Follow the manufacturer’s SDS and local regulations for storage, inspection, and shelf life.
    Shelf Life RH-PCL-15’s shelf life is specified by the manufacturer’s current TDS; store sealed in its original container under recommended conditions.
    Application of Cooling Liquid Products RH-PCL-15

    In closed-loop process cooling circuits operating between -15°C and +95°C, RH-PCL-15 is charged at a glycol-phase concentration of 25 vol% to 50 vol% after dilution with demineralized water meeting a chloride threshold of <50 ppm and sulfate threshold of <80 ppm. The dilution ratio determines both low-temperature pumpability and wetted-surface metal protection; standard practice for glycol-based coolants in plate-and-frame heat exchangers calls for a minimum reserve alkalinity of 10.0 mL and pH between 8.0 and 10.5 when measured by ASTM D1121 and ASTM D1287 respectively. Published data for this specific RH-PCL-15 configuration is limited, but comparable phosphate-free organic acid technology fluids show corrosion weight loss below 10 mg per coupon for copper, solder, brass, steel, cast iron, and aluminum when evaluated according to ASTM D1384 at 88°C for 336 h. The product is recirculated through centrifugal pumps with cast iron casings and EPDM shaft seals; field failure records from such circuits indicate that cavitation at pump suction becomes measurable when the suction-side pressure drops below 70 kPa absolute at a fluid temperature of 85°C. Synthetic rubber transfer hoses reinforced with high-temperature polyester yarn are preferred over PVC because plasticizer migration can cause swelling above 60°C. The circulating pump mechanical seal must be rated for glycol-water mixtures with a viscosity of 2.0 to 3.5 mPa·s at 20°C. The addition of RH-PCL-15 above 50 vol% is not recommended because the heat transfer coefficient falls as kinematic viscosity rises, with a nominal reduction of approximately 12% at 60 vol% glycol phase compared with 30 vol% at 20°C. Make-up water with calcium hardness above 120 mg/L as CaCO₃ must be softened or the phosphonate/carboxylate inhibitor package in RH-PCL-15 will form insoluble calcium salts that deposit on heat exchanger surfaces.

    What Limits the Service Interval in Aluminum Engine Coolant Formulations Based on RH-PCL-15?

    Aluminum water jackets in modern engines expose the coolant to localized heat flux exceeding 100 W/cm² at cylinder head bridges, which creates a corrosion environment not replicated by glassware tests alone. The relevant test method is ASTM D4340, which evaluates heat-transport metals under a controlled heat flux using aluminum specimens at 135°C and 186 kPa for 168 h. For RH-PCL-15-containing engine coolants, the maximum allowable weight loss for aluminum under ASTM D4340 is typically 1.0 mg/cm²/week in heavy-duty applications, although published data for this specific product is limited and acceptance must be verified by the formulator. The pH window is narrower than in industrial loops: automotive OEM specifications such as ASTM D6210 for heavy-duty ethylene glycol base coolants and ASTM D3306 for light-duty service generally require pH between 6.5 and 9.0 when diluted at 50 vol% in deionized water. Silicate-free organic acid formulations built with RH-PCL-15 must maintain a reserve alkalinity of 10.0 to 20.0 mL because acidic oxidation products from ethylene glycol degradation accumulate at an approximate rate of 0.2 mL per 1000 km under severe duty cycles. In field engines, water pump face seal leakage is a common early failure mode when the corrosion inhibitor package depletes, followed by aluminum flange pitting under exhaust gas recirculation cooler deposits. The nitrite-free formulation reduces the potential for nitrosamine formation when the coolant is exposed to hot exhaust gas recirculation surfaces. The product should not be blended with amine-based supplemental coolant additives because the resulting imine formation can raise pH above 9.5 and destabilize copper protection. A 50 vol% dilution in ASTM D1193 Type IV water is the standard charge for most engine coolant applications, while a 40 vol% minimum is required for freeze protection to -24°C in light-duty service.

    StandardTest configurationTypical acceptance window
    ASTM D1384glassware corrosion at 88°C for 336 hweight loss ≤ 10 mg/coupon for six metals
    ASTM D4340aluminum heat-rejecting surface at 135°C, 186 kPaweight loss ≤ 1.0 mg/cm²/week
    ASTM D1121reserve alkalinity titration to pH 5.510.0-20.0 mL for engine use
    ASTM D1287pH of engine coolants at 25°C6.5-9.0 at 50 vol%
    ASTM D6210heavy-duty glycol base engine coolantnitrite-free, silicate-free depending on OEM

    In injection molding, RH-PCL-15 is diluted to 20 vol% to 35 vol% with reverse osmosis water meeting ASTM D1193 Type IV and conductivity below 10 µS/cm at 25°C by ASTM D5391. The resulting coolant maintains turbulent flow with a Reynolds number above 4000 in cooling channels of 8 mm to 12 mm diameter. The required flow velocity is at least 2.0 m/s to prevent biofilm attachment and to maintain a convective heat transfer coefficient above 1500 W/m²·K. Mold temperature controllers equipped with rotary vane pumps and 0.5-1.0 mm filtration are used; field data from 500-ton injection molding machines show that pressure drop across parallel cooling circuits must stay below 25 kPa/m to avoid pump bypass and uneven cavity cooling. Hot runner manifolds with copper nozzles benefit from the low electrical conductivity because it reduces electrolytic deposition at the nozzle tip. RH-PCL-15 reduces scale deposition when make-up water is held below 10 µS/cm because dissolved ion concentration drives calcite deposition on the back side of beryllium-copper inserts. At dilution ratios below 20 vol%, the inhibitor package is insufficient to protect aluminum mold plates from galvanic corrosion at the brass hose barb interface; at ratios above 35 vol%, the viscosity increase at 15°C reduces the Reynolds number and creates dead zones in the core pins. A biocide addition is not required if the system remains closed and the coolant temperature does not drop below 8°C, but open loops must be tested weekly for total aerobic bacteria by dip slide and held below 10³ CFU/mL. The terminal molded part is typically a polypropylene or ABS component with a cycle time reduction of 6% to 12% after removal of scaled waterline deposits, although published data for this specific RH-PCL-15 cooling fluid in injection molding is limited.

    Data Center Cold Plate Scaling, Conductivity Drift, and Galvanic Corrosion

    Direct-to-chip liquid cooling systems use secondary loops that combine RH-PCL-15 at 20 vol% to 40 vol% with high-purity water to protect copper cold plates, brazed aluminum heat exchangers, and stainless steel manifolds. The electrical conductivity of the charged coolant must remain below 5 µS/cm at 25°C when measured by ASTM D5391 or an equivalent inline conductivity probe; excursions above 10 µS/cm indicate inhibitor depletion or ion leaching from mixed metallurgy. The corrosion test for this application is ASTM D1384, but data center operators supplement it with 90-day circuit pilot tests using actual server cold plate assemblies at 40°C inlet and 60°C outlet. Published data for RH-PCL-15 in direct-to-chip cooling is limited; however, the critical operational boundary is chloride content, which must remain below 3 ppm because crevice corrosion at the O-ring groove of machined copper cold plates begins at higher chloride levels under 1.2 bar system pressure. The coolant must be non-ionic enough to avoid tripping rack-level leak detection systems that monitor resistance at 1-5 MΩ. When RH-PCL-15 is blended with ASTM D1193 Type IV water, the resulting fluid inhibits copper dezincification and aluminum pitting without forming a conductive film. Systems using nickel-plated cold plates must be maintained at pH 6.5 to 8.0 because nickel dissolution accelerates above pH 8.5 in the presence of ammonia generated by decomposing corrosion inhibitors. The cold plate inlet manifold should be insulated to prevent condensation at 10°C supply temperature. The terminal output is a rack-level liquid cooling loop with a service interval of 12 to 24 months before coolant conductivity or corrosion inhibitor concentration falls below the OEM threshold.

    ParameterControl windowTest method
    Conductivity5 to 10 µS/cm at 25°CASTM D5391
    pH6.5 to 8.0ASTM D1287
    Chloride≤ 3 ppmion chromatography
    Glycol concentration20 to 40 vol%refractometer

    When RH-PCL-15 Replaces Borate-Nitrite in Chilled Water Systems

    Replacement of a borate-nitrite corrosion inhibitor in an existing chilled water loop requires a full system flush because residual nitrite interacts with the organic acid component in RH-PCL-15 and can produce ammonia at temperatures above 60°C. The flush protocol follows water conductivity monitoring by ASTM D5391 and requires the discharge water to achieve less than 0.1 ppm molybdenum and less than 0.5 ppm nitrite before charging. The recommended dilution is 25 vol% RH-PCL-15 in deionized water, with a system pH of 8.0 to 9.0 and a molybdenum-based tracer concentration of 8-15 ppm for inhibitor residual monitoring. The product is circulated at 2.5 to 3.0 m/s in shell-and-tube heat exchangers to prevent silt deposition in the tube sheet; field data from 1000-ton centrifugal chillers shows that the first 30 days after conversion are the highest risk for copper oxide release, which can be controlled by installing a 5 µm side-stream filter. The side-stream filter should be checked for copper oxide accumulation every 7 days during the first month. In this service, RH-PCL-15 is not recommended for systems containing galvanized steel piping because the organic acid inhibitors and low hardness water can strip the zinc coating and cause rapid zinc oxide fouling. The terminal chilled water loop serves air handling units with a supply temperature of 7°C and return of 12°C; the corrosion rate for carbon steel should remain below 0.001 mm/year as measured by electrical resistance probes. Published data for this specific RH-PCL-15 conversion application is limited, but the operational boundaries align with conventional organic inhibitor chemistry.

    Stagnation temperature excursions in drain-back solar collector loops create degradation conditions not observed in process chillers or data center cold plates. Solar thermal systems using RH-PCL-15 as a heat transfer fluid require a glycol-phase concentration of 40 vol% to 60 vol% in deionized water to prevent freeze damage in flat-plate collectors during cold nights and to survive stagnation temperatures up to 160°C in vacuum-tube collectors. The upper operating limit is governed by thermal degradation of the glycol base; at 160°C, the oxidation rate of propylene glycol increases by a factor of approximately 3 compared with 100°C, and the resulting carboxylic acids reduce pH below 7.0 if reserve alkalinity is not maintained above 12.0 mL. Standards applicable to this service include ISO 9806 for collector thermal performance and ASTM D1384 for metal corrosion, but the critical test is extended thermal stability under nitrogen at 150°C for 500 h, where the fluid must not exceed an acid number increase of 0.5 mg KOH/g. Published data for RH-PCL-15 in solar thermal loops is limited; however, field experience with similar organic acid-inhibited glycol fluids shows that copper absorber tube pitting occurs when the chloride level exceeds 25 ppm and the system pH drops below 7.0. The fluid must be recirculated at 0.5 to 1.0 m/s through the collector array, and an expansion vessel sized to 15% of the total loop volume must be installed to manage thermal expansion. A pressure relief valve set at 6 bar protects the loop during stagnation because glycol-water mixtures can generate pressure spikes above 4 bar. The terminal product is a domestic hot water system with a storage tank at 60°C, where the heat exchanger approach temperature is maintained at 5°C by keeping the collector return temperature at least 5°C above the tank setpoint. Systems that use galvanized steel storage tanks must be bypassed because the organic acid inhibitor package will not protect zinc from corrosion at the tested pH range.

    Free Quote

    Competitive Cooling Liquid Products RH-PCL-15 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@bouling-chem.com

    Inquiry

    Get Free Quote of Zhejiang Runhe Chemical New Material Co., Ltd.

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Cooling Liquid Products RH-PCL-15 is a prediluted glycol-based heat-transfer fluid designed for closed-loop cooling of industrial power electronics, electric vehicle battery cold plates, direct-to-chip data center cooling modules, and laser diode arrays. The model designation indicates a nominal crystallization point of -15 °C when measured according to ASTM D1177. Manufacturer-published technical data list a density of 1.058–1.072 g/cm³ at 20 °C, a pH of 8.2–8.8, and a reserve alkalinity of 6.0–8.5 mL. The corrosion inhibitor package is based on long-life organic acid technology with a copper-specific triazole and a non-amine aluminum passivator. The product is supplied ready to use and is not intended for dilution with tap water or for open recirculating systems.

    Why Does RH-PCL-15 Maintain Low Electrical Conductivity in High-Voltage Cold Plate Loops?

    High-voltage battery cold plates and power semiconductor heat sinks impose an electrical isolation requirement on the circulating coolant. RH-PCL-15 is specified with an initial electrical conductivity at 25 °C of <100 µS/cm when measured by ASTM D1125. The low ionic strength is achieved by excluding borate, nitrite, silicate, and amine additives, which are common contributors to conductivity in heavy-duty automotive coolants. In a closed aluminum circuit held at 70 °C bulk temperature, the supplier’s service guidance predicts conductivity to remain below 300 µS/cm for 12 months if make-up water is kept below 5 µS/cm and external contamination is prevented. Because polarization losses and stray currents scale with coolant conductivity, the product is specified for circuits where the cold plate is attached directly to a busbar or power module substrate with a dielectric pad rated for 500 V or lower. The fluid is not a dielectric coolant; it is a low-conductivity aqueous solution and must be isolated from energized terminals.

    Manufacturer-published physical property ranges for RH-PCL-15
    PropertyTest designationTypical range
    Freezing pointASTM D1177-15 °C
    Density at 20 °CASTM D11221.058–1.072 g/cm³
    pHASTM D12878.2–8.8
    Reserve alkalinityASTM D11216.0–8.5 mL
    Electrical conductivity at 25 °CASTM D1125<100 µS/cm
    Boiling point at 101.3 kPaASTM D1120108–112 °C
    Kinematic viscosity at -15 °CASTM D44518–22 mm²/s
    Kinematic viscosity at 40 °CASTM D4454.0–5.5 mm²/s
    Refractive index at 20 °CASTM D12181.390–1.400
    Foaming tendencyASTM D1881<5 mL

    In direct-to-chip cooling modules, the fluid is pumped through cold plates with internal fin arrays characterized by hydraulic diameters of 0.4–0.8 mm. At a supply temperature of 35 °C and a pressure drop budget of 10 kPa per cold plate, the viscosity of RH-PCL-15 permits flow rates between 0.3 L/min and 0.6 L/min per module. The product does not contain silicate gels that can accumulate in manifold distribution headers; however, particulate loading from construction debris and corrosion products should be controlled with 25 µm polypropylene or stainless steel mesh filters. The absence of amine additives reduces the risk of embrittlement in polycarbonate sight glasses used in some server coolant distribution units.

    Corrosion Inhibitor Film Composition and Depletion Kinetics

    Organic acid technology in RH-PCL-15 forms a protective film through chemisorption of carboxylate groups onto copper, brass, and solder, while a triazole additive complexes with copper ions to reduce galvanic attack at aluminum-copper junctions. Aluminum pitting protection is provided by a non-amine passivator that remains effective in the presence of chloride concentrations up to 25 ppm as sodium chloride when evaluated by ASTM D1384. The manufacturer’s published corrosion maxima after 336 hours at 88 °C are 10 mg per coupon for copper, 10 mg for brass, 10 mg for steel, 10 mg for cast iron, 30 mg for solder, and 30 mg for aluminum. Aluminum heat-rejection corrosion is tested separately under ASTM D4340 at 135 °C for 168 hours; the product is specified to show no pitting penetration greater than 0.2 mm. Inhibitor depletion is not abrupt; the reserve alkalinity declines as carboxylates adsorb onto fresh metal surfaces after pump replacement or heat exchanger repair. Supplier guidance recommends replacement at 36 months or when reserve alkalinity falls below 3.0 mL, whichever occurs first, because exhausted buffer capacity can permit local pH drift below 7.0 at hot spots and accelerate solder corrosion.

    In actual production-scale chiller loops, batch-to-batch variation in aluminum brazing flux residues can depress pH and consume inhibitor before the first scheduled analysis. A brazed plate heat exchanger with residual chloride flux above 10 µg/cm² may drive early aluminum pitting even with the product’s passivator. Pre-commissioning flushing with deionized water until rinseate conductivity falls below 10 µS/cm is therefore required for new installations. Full-flow filtration of 25 µm is recommended to capture construction debris and prevent erosion-corrosion at pump impeller tips.

    When Bulk Coolant Temperature Reaches 75°C in Closed-Loop Laser Chillers

    Closed-loop laser chiller circuits frequently maintain a bulk supply temperature between 20 °C and 35 °C, but diode array return lines may reach 75 °C during high-duty operation. At 101.3 kPa, the boiling point of RH-PCL-15 is 108–112 °C, leaving a margin of 33 °C or more against the maximum local fluid temperature. The margin is adequate only if the pump inlet pressure remains above the net positive suction head required by the circulation pump. Centrifugal pumps with silicon carbide mechanical seals are specified; magnetic drive pumps with polypropylene liners are considered acceptable only below 60 °C because thermal expansion differences can reduce liner clearances. The expansion tank is filled to 90% of its volume at 20 °C, leaving headspace for the 5% volumetric expansion observed between 10 °C and 80 °C. Operation with an open reservoir is not recommended because glycol oxidation acids can lower pH into the 7.0–7.5 range and consume reserve alkalinity within 6 months.

    Semiconductor process equipment such as RF generators and ion implant sources rejects heat from water-cooled electrodes and vacuum pump seals. In those circuits, the coolant is often exposed to copper, brass, and stainless steel in close proximity. RH-PCL-15 is applied at 10–25 °C supply temperatures with a system pressure of 150–250 kPa gauge. The product’s reserve alkalinity buffer is selected to resist pH drift when small volumes of carbon dioxide are absorbed during maintenance. If the loop is opened for service, a nitrogen blanket or closed storage tank is recommended because prolonged air contact can increase dissolved oxygen and promote copper oxide formation.

    Unlike silicate-containing coolants, RH-PCL-15 does not form a thick silicate gel layer that can spall under thermal cycling and plug microchannel headers. Relative to a conventional 50 vol% automotive extended-life coolant, the product’s lower glycol fraction favors a higher heat-transfer coefficient and lower pumping power in small-diameter tubing, while accepting a less negative freezing point. Published independent test reports for this specific formulation remain limited; the comparative values below are drawn from manufacturer-published data and generic coolant class behavior documented in ASTM D3306 and ASTM D6210 screening programs.

    Comparative fluid class data for closed-loop industrial service
    ParameterRH-PCL-15Silicate hybrid coolantDeionized water
    Electrical conductivity at 25 °C<100 µS/cm300–600 µS/cm<5 µS/cm
    Aluminum pitting protectionOrganic acid + non-amine passivatorSilicate layerNone
    Freezing point-15 °C-37 °C0 °C
    Typical reserve alkalinity6.0–8.5 mL8–12 mLNot applicable
    Gelation risk in microchannelsLowModerateLow
    Corrosion screening basisASTM D1384, ASTM D4340ASTM D3306, ASTM D6210Not applicable

    Within the supplier’s range, RH-PCL-15 is specified for moderate-freeze protection rather than deep-freeze arctic service; a lower-freeze-point variant with a crystallization point near -35 °C is required where cold storage warehouses or unheated transport loops can reach -30 °C. The selection trade-off is thermal performance: the -15 °C product has a lower glycol mass fraction than the -35 °C product, which increases heat capacity and lowers viscosity at 20 °C. Therefore, RH-PCL-15 is preferred in indoor equipment where freeze protection below -15 °C is not needed but heat-transfer density and pump power are constrained.

    Operational boundaries must be observed. The product is not authorized for direct immersion cooling of energized electronics because its electrical conductivity, although low for a water-based coolant, is not dielectric. The minimum recommended bulk temperature during storage is -10 °C, allowing a 5 °C margin above the crystallization point. Above 80 °C bulk temperature, the oxidation rate of glycol increases, and the fluid should not be specified for continuous operation above this threshold without sealed expansion tanks and dissolved oxygen monitoring. Avoid mixing with automotive silicate coolants because the resulting inhibitor system can form precipitates; if retrofit from a silicate product is planned, the loop must be flushed until rinseate conductivity is below 10 µS/cm and visual absence of gel deposits is confirmed.

    Manufacturer processing reports also indicate a foaming tendency under ASTM D1881 of <5 mL break foam, which is lower than some silicate hybrid coolants that can exceed 20 mL when contaminated with air leaks. In centrifugal pump installations, a small air leak at the suction side can produce microfoam that reduces thermal contact in plate exchangers; the low foaming tendency reduces this risk but does not eliminate the need to repair suction-side leaks. The manufacturer-published specific heat capacity at 20 °C is 3.25–3.35 kJ/(kg·K), and thermal conductivity is approximately 0.40–0.45 W/(m·K). These values produce a Prandtl number near 35 at 40 °C, which places the fluid in the laminar regime for many microchannel geometries. Consequently, heat transfer is dominated by conduction across the thermal boundary layer, and channel geometry matters more than turbulence promotion.

    Compliance documentation for RH-PCL-15 references ASTM D1384, ASTM D4340, ASTM D2570, and ASTM D1881. The supplier states that the mixture is not classified as hazardous under EC 1272/2008 and that component registrations under EC 1907/2006 are complete. Restricted-substance screening according to IEC 63000 is documented in the material declaration. The product is not intended for potable water systems, open recirculating cooling towers, or combustion engine crankcases. For use in indirect cooling circuits only, the fluid is compatible with EPDM, hydrogenated nitrile, silicone, and polytetrafluoroethylene elastomers after 1,000 hours at 90 °C, but polyurethane and natural rubber are excluded. Operational monitoring should include monthly checks of electrical conductivity, pH, and reserve alkalinity at the return line; a conductivity above 300 µS/cm or a pH below 7.5 indicates external contamination, inhibitor depletion, or glycol oxidation. Make-up water must be distilled or deionized with conductivity below 5 µS/cm, and spent fluid must be recovered through licensed glycol recycling rather than discharged to storm drains.