| HS Code | 176336 |
| Productname | Cooling Liquid Products RH-PCF-5 |
| Chemicalfamily | Perfluorocarbon (PFC) |
| Chemicalname | Perfluoropentane |
| Molecularformula | C5F12 |
| Molecularweight | 288.03 g/mol |
| Casnumber | 678-26-2 |
| Boilingpoint | 29 °C at 760 mmHg |
| Freezingpoint | -90 °C |
| Density | 1.63 g/cm³ at 25 °C |
| Dynamicviscosity | ≈0.5 mPa·s at 25 °C |
| Specificheatcapacity | ≈1.05 J/g·K |
| Thermalconductivity | ≈0.059 W/m·K |
| Dielectricconstant | ≈1.8 |
| Dielectricstrength | ≥40 kV/mm |
| Volumeresistivity | >1×10^15 Ω·cm |
| Surfacetension | ≈10.5 mN/m |
| Vaporpressure | ≈75 kPa at 25 °C |
| Flashpoint | None (nonflammable) |
| Appearance | Clear, colorless liquid |
| Odor | Odorless |
| Watersolubility | Negligible |
| Ozonedepletionpotential | 0 |
As an accredited Cooling Liquid Products RH-PCF-5 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Packaged in a 5 L (1.3 gal) HDPE bottle with screw cap and chemical-resistant label for safe handling. |
| Container Loading (20′ FCL) | Cooling Liquid Products RH-PCF-5 loaded in a 20′ FCL container, securely packed and stowed for ocean shipment. |
| Shipping | Cooling Liquid Products RH-PCF-5 should be shipped in sealed, compatible containers, clearly labeled and secured against leakage or tipping. Transport according to the current SDS and applicable regulations; protect from extreme temperatures and physical damage. Verify hazard classification, UN number, packing group, and required documentation before shipment. |
| Storage | Store RH-PCF-5 in its original, tightly closed container in a cool, dry, well-ventilated area. Protect from direct sunlight, heat, ignition sources, and freezing. Keep away from strong oxidizers, incompatible materials, food, feed, and drinking water. Use secondary containment, prevent leaks or spills, maintain clear labeling, and follow the manufacturer’s Safety Data Sheet and local regulations. |
| Shelf Life | RH-PCF-5 has a shelf life of approximately two years when stored sealed at recommended temperatures, away from sunlight and freezing. |
In direct-to-chip and rear-door heat exchanger loops, the finished working fluid is prepared by blending RH-PCF-5 with reverse-osmosis permeate or deionized water that meets the resistivity target of the coolant distribution unit. A starting dilution of 20–35 vol% is used only after the freeze point is confirmed by ASTM D1177; the exact ratio is dependent on the installed chiller setpoint, outdoor dry-bulb exposure, and the freeze-protection margin required by the site risk assessment. Filtration through a 5 µm absolute-rated bag filter is performed during initial fill, and a side-stream ion-exchange cartridge is kept in service until conductivity stabilizes below the server manufacturer’s limit, frequently 10 µS/cm at 25 °C when measured by ASTM D5391. The terminal product is not a discrete manufactured item but the circulating working fluid inside the cold-plate loop, delivered through the CDU to quick disconnects, copper or nickel-plated cold plates, and return manifolds. Flow velocity is maintained between 1.0 m/s and 2.5 m/s to prevent erosion-corrosion of brazed plate heat exchanger nickel foil while avoiding sedimentation of particulates. Pressure decay testing is conducted at 1.5 times the operating pressure for a minimum of 24 h before the loop is accepted. Because data center operators run with oxygen-permeable polymer tubing, the fluid is not left stagnant for more than 72 h without circulation, and dissolved oxygen ingress is controlled by closed-loop expansion tank blanketing.
Closed hydronic loops serving air-handling units, fan-coil units, and geothermal heat pumps are charged with RH-PCF-5 at 30–50 vol% to provide freeze protection to −20 °C or lower, depending on the base fluid and the measured freezing point from ASTM D1177. The cooling or heating terminal product is the treated water-glycol solution circulating through carbon steel piping, ductile iron pumps, and brazed plate heat exchangers. A coupon rack containing copper, solder, brass, steel, cast iron, and cast aluminum is installed in a bypass loop for 90 days and evaluated by gravimetric mass loss under ASTM D1384; mass-loss values outside the specification limits for cast aluminum and solder are a signal that the inhibitor package has been depleted by dilution, overheating, or aeration. Reserve alkalinity is measured by ASTM D1121, and pH is maintained between 8.0 and 9.5 using ASTM D1287 at the point of sampling. The system is pre-cleaned with a 1–2 wt% trisodium phosphate or inhibited acid cleaner only when the piping has visible corrosion, sludge, or oil contamination, followed by triple rinsing until the rinse water conductivity matches the municipal supply. Fluid is introduced through a side-stream 10 µm filter at a fill velocity not exceeding 1.5 m/s to displace air through automatic vents at high points. The operational boundary is a maximum continuous bulk temperature of 90 °C for ethylene glycol-based versions because higher temperatures accelerate oxidative acid formation and deplete buffer alkalinity. If the system contains galvanized steel, the fluid temperature is kept below 70 °C because zinc corrosion accelerates sharply above this threshold. Hard water with total hardness above 150 mg/L as CaCO₃ is not used for dilution because calcium precipitates with certain inhibitor anions and fouls plate heat exchangers. The same bypass coupon rack is reweighed after 12 months to determine whether inhibitor adjustment or partial drainage is necessary.
| Standard | Parameter measured | Relevance to RH-PCF-5 service |
|---|---|---|
| ASTM D1384 | Corrosion mass loss in glassware | Evaluates copper, solder, brass, steel, cast iron, and cast aluminum in a mixed-metal circuit |
| ASTM D3306 | Light-duty engine coolant specification | Sets freeze point, foaming, pH, and corrosion limits for automotive and test-cell service |
| ASTM D6210 | Heavy-duty engine coolant specification | Addresses liner pitting and cavitation in higher thermal load circuits |
| ASTM D1177 | Freezing point of aqueous solutions | Verifies dilution ratio before winter start-up and after field top-up |
| ASTM D5391 | Electrical conductivity of flowing water | Detects ionic contamination in data center, battery, and laser cooling loops |
| ASTM D1121 | Reserve alkalinity | Tracks inhibitor depletion and acid formation in hot closed loops |
| ASTM D1287 | pH of engine coolants | Controls aluminum compatibility and buffer capacity |
| ASTM D1881 | Foaming tendency | Prevents cavitation and overflow in test cells and TCUs |
In engine dynamometer coolant circuits, RH-PCF-5 is circulated through the engine block, cylinder head, EGR cooler, and load cell heat exchanger at a typical concentration of 50–60 vol% in deionized water to satisfy the boiling point and cavitation-corrosion requirements of ASTM D6210 or ASTM D3306 for light-duty test articles. The terminal product is the heat transfer fluid inside the closed engine test cell loop, which must maintain stable pH, reserve alkalinity, and low foaming under repeated thermal cycling from cold start to full-load operation. During a test sequence, the coolant bulk temperature is often held at 110–125 °C with a 15 psi pressure cap; excursions above 135 °C accelerate oxidative degradation and produce acetic and formic acid fragments, causing a drop in reserve alkalinity measured by ASTM D1121. The test cell operator monitors the freezing point by ASTM D1177 after each engine rebuild because residual rinse water in the block can dilute the fluid by 5–15 vol%. Foaming is controlled to a maximum of 50 mL according to ASTM D1881; excessive foam leads to pump cavitation and uneven cooling in the cylinder head. The process for filling includes vacuum-assisted evacuation of the engine water jacket to remove trapped air in the EGR cooler and heater core, followed by pressure filling at 0.7–1.0 bar with a 100 µm suction strainer on the transfer pump. Incompatibility boundaries include avoidance of top-up with nitrite-containing heavy-duty coolant unless the RH-PCF-5 supplier has certified chemical compatibility, because mixed inhibitor chemistries can deplete nitrite and cause liner pitting. The coolant is not used in open-top test stands exposed to direct sunlight or uncontrolled air entrainment, because oxidation of glycol and depletion of inhibitors will occur within 30–60 days under those conditions.
Before a battery thermal management loop is filled with RH-PCF-5, the wetted path is checked for copper, stainless steel, and 3000-series aluminum cold plate compatibility because galvanic couples between a copper busbar and an aluminum cold plate can generate localized corrosion if the coolant conductivity is not controlled. The filling ratio is typically 25–50 vol% with high-purity water, and the finished working fluid circulates through the battery pack’s serpentine cold plate, the chiller heat exchanger, and the expansion tank. Conductivity is measured continuously at the CDU using ASTM D5391; an upper limit of 10 µS/cm at 25 °C is a common OEM requirement, but the specific RH-PCF-5 batch limit must be taken from the technical data sheet because some inhibitor chemistries are more conductive than others. Vacuum filling is used to ensure that parallel cold plate channels are fully wetted, followed by a 30-minute circulation at 0.5 m/s with a 5 µm membrane filter to remove installation debris. The process temperature is typically 15–30 °C inlet to the pack and 20–40 °C outlet, with flow rate balanced to keep the temperature spread across cells below 5 °C. The terminal product is the thermally conditioned battery pack or stationary storage module, but the fluid itself is a consumable maintenance item that is sampled quarterly for pH by ASTM D1287 and for inhibitor concentration by ASTM D1122 specific gravity. A known incompatibility is the use of hard tap water, which raises the conductivity and precipitates calcium carbonate on the plate heat exchanger after 500–1000 h of operation. If the loop is opened for cell replacement, the drained fluid is not reused without re-filtration and conductivity adjustment because copper ions from the cold plate can plate out on aluminum surfaces and accelerate corrosion.
For food and beverage processing plants that require a secondary cooling loop adjacent to pasteurizers, plate chillers, and jacketed tanks, RH-PCF-5 is evaluated as a propylene glycol-based working fluid only when the supplier documentation confirms compliance with FDA 21 CFR 184.1666 for propylene glycol identity or NSF/ANSI/CAN 60 for incidental contact in potable water systems. The dilution ratio is adjusted to 25–40 vol% based on the lowest refrigerated surface temperature, typically −10 °C to −20 °C, and is verified by ASTM D1177 using a refractometer calibrated for propylene glycol. The terminal product is the heat transfer fluid circulating through stainless steel plate heat exchangers, food-contact cooling jackets, and packaging line chillers; the fluid does not directly touch food. Process setup includes a flush with potable water until the rinse water meets the plant’s microbial sampling limit, followed by the addition of RH-PCF-5 through a 20 µm cartridge filter and an ultraviolet disinfection unit if the system is open to atmosphere during maintenance. System pressure is maintained at 1.0–2.0 bar above thermal expansion pressure to prevent air ingress. The temperature boundary is −25 °C at the low end and 90 °C at the high end for continuous service, because propylene glycol viscosity rises at low temperature and heat transfer coefficient drops rapidly below −20 °C if the concentration exceeds 45 vol%. The fluid is not mixed with ethylene glycol-based coolants in the same plant because the two base fluids have different refractive index slopes, and cross-contamination can create a toxicological labeling violation under 21 CFR 184 if food contact is possible. In breweries and dairy plants, the use of propylene glycol in chiller loops is often documented under the plant’s ISO 22000 prerequisite program, and the fluid is tested annually for pH by ASTM D1287 and for corrosion inhibitors using the supplier’s designated titration method.
Injection mold temperature control units require a fluid that remains stable during repeated heat-up to 120 °C and cool-down to 20 °C, where thermal expansion and contraction can draw air into the circuit. RH-PCF-5 is blended at 10–30 vol% with demineralized water for freeze protection only where the plant’s cooling tower or chiller can be exposed to freezing temperatures; for high-temperature mold service above 120 °C, the concentration is kept at the lower end because glycol degradation accelerates under high heat flux at the mold wall. The finished working fluid circulates through the mold cooling channels, TCU heater, and heat exchanger, and the terminal product is the thermally controlled injection mold producing parts with consistent cycle time and dimensional stability. Branch runs to parallel mold halves are balanced by flow meters so that the Reynolds number in each circuit is kept above 4000, ensuring turbulent flow that prevents fouling and scale deposition on the steel channel walls. Particulate control is provided by a 100 µm return-line strainer and a 10 µm bypass filter. The fluid is sampled at the return manifold for pH by ASTM D1287 and for ferrous debris by inductively coupled plasma spectroscopy if the plant suspects internal corrosion. Aluminum mold plates are protected only when the pH remains between 7.0 and 9.0; above 9.5, alkaline attack on aluminum can cause channel wall pitting and water leakage into the mold cavity. The system is not filled with hard water containing more than 100 mg/L calcium hardness because mineral scale on the heater elements reduces heat transfer and creates hot spots. If the TCU is idle for more than 14 days, the circuit is drained or circulated weekly to prevent biological growth and inhibitor settling.
| Application sector | Starting RH-PCF-5 concentration | Target temperature boundary | Primary verification |
|---|---|---|---|
| Data center cold plate loop | 20–35 vol% | 10–40 °C | ASTM D5391, ASTM D1177 |
| Closed hydronic HVAC | 30–50 vol% | −20 °C to 90 °C | ASTM D1177, ASTM D1121 |
| Engine test cell | 50–60 vol% | 110–125 °C bulk | ASTM D6210, ASTM D1881 |
| Battery thermal management | 25–50 vol% | 15–40 °C | ASTM D5391, ASTM D1287 |
| Indirect food-contact chiller | 25–40 vol% | −25 °C to 90 °C | NSF/ANSI/CAN 60, ASTM D1177 |
| Injection mold TCU | 10–30 vol% | 20–120 °C | ASTM D1287, flow confirmation |
| Laser cooling loop | 20–50 vol% | 10–30 °C | ASTM D5391, ISO 4406 |
| Secondary-loop refrigeration | 35–50 vol% | −40 °C to 80 °C | ASTM D1177, ASTM D1121 |
In laser cutting and medical laser systems, the cooling loop must manage both sensible heat from the resonator and waste heat from the RF power supply, while keeping ionic contamination low enough to avoid electrocorrosion of copper and brass fittings. RH-PCF-5 is diluted with high-purity deionized water to 20–50 vol% depending on the laser tube manufacturer’s freeze protection and optical table temperature requirements, and the finished working fluid circulates through the laser tube jacket, safety shutter, and heat exchanger. The terminal product is the thermally stable laser output during continuous operation, because even small temperature fluctuations change the resonator length and beam mode. Conductivity is measured before each shift using ASTM D5391; an increase above the initial stabilized value by more than 5 µS/cm indicates that metal ions or airborne salts have entered the loop, and a side-stream mixed-bed ion-exchange cartridge is installed to restore low conductivity. Dissolved oxygen is controlled by nitrogen blanketing of the expansion tank when the system is shut down for more than 48 h. Particulate contamination is held to ISO 4406 code 18/16/13 by a 3 µm absolute-rated filter in the return line, because optical-pump cooling channels are sensitive to silting. The fluid is not topped up with tap water, and the filling process uses vacuum-assisted transfer through Tygon or silicone hose that has been flushed with deionized water to avoid introducing soluble plasticizer into the loop. A known limitation is that high glycol concentrations above 50 vol% reduce the heat transfer coefficient and increase viscosity at 10 °C, which can cause the laser power supply temperature to exceed its alarm threshold. The used coolant is collected and tested for copper and zinc by inductively coupled plasma spectroscopy before disposal under local effluent limits.
Secondary-loop refrigeration and heat pump systems use RH-PCF-5 as a heat transfer brine when the primary refrigerant is confined to a machine room and the chilled or heated fluid is distributed through a building. The working solution is prepared at 35–50 vol% for freeze protection to −25 °C to −40 °C, verified by ASTM D1177, and the terminal product is the chilled or warm fluid feeding display cases, cold rooms, fan-coil units, or ice rink slabs. The circuit is filled through a 50 µm fill filter and circulated at a velocity of 1.0–2.0 m/s in carbon steel pipe; velocities below 1.0 m/s allow suspended sludge to settle, while velocities above 2.5 m/s increase erosion in copper elbows. A pressure test at 1.3 times the design pressure is performed for 24 h before the system is charged. The fluid is monitored for pH by ASTM D1287, for freezing point by ASTM D1177, and for inhibitor reserve by ASTM D1121 on an annual schedule. Published field data for this specific RH-PCF-5 formulation in secondary-loop supermarket refrigeration is limited; however, the process boundaries described here follow the indirect system commissioning practices of EN 378 and the corrosion evaluation methods of ASTM D1384. Incompatible materials include uncoated galvanized tanks at temperatures above 70 °C, and ammonia leak detectors in the loop must be selected for glycol service because the fluid can coat sensors and slow response. The system is not operated as an open brine loop because continuous oxygen ingress accelerates inhibitor depletion and acid formation.
Competitive Cooling Liquid Products RH-PCF-5 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
| Property | Typical Value | Test Method |
|---|---|---|
| Kinematic viscosity at 25 °C | 0.65 cSt | ASTM D445 |
| Density at 25 °C | 1.62 g/cm³ | ASTM D4052 |
| Pour point | -90 °C | ASTM D97 |
| Initial boiling point | 175 °C | ASTM D1120 |
| Specific heat at 25 °C | 1.10 kJ/kg·K | ASTM E1269 |
| Thermal conductivity at 25 °C | 0.065 W/m·K | ASTM D2717 |
| Volume resistivity at 25 °C | 1.0 × 10¹⁵ ohm·cm | ASTM D257 |
| Dielectric strength, 2.5 mm gap | 42 kV | ASTM D877 |
| Flash point | none observed | ISO 2719 |
| Total acid number as received | 0.02 mg KOH/g | ASTM D664 |
| Parameter | RH-PCF-5 | Mineral oil | 50% inhibited glycol | Hydrofluoroether |
|---|---|---|---|---|
| Kinematic viscosity at 25 °C | 0.65 cSt | 12 cSt | 3.5 cSt | 0.4 cSt |
| Density at 25 °C | 1.62 g/cm³ | 0.87 g/cm³ | 1.07 g/cm³ | 1.50 g/cm³ |
| Pour point | -90 °C | -12 °C | -38 °C | -135 °C |
| Flash point or boiling threshold | none / 175 °C initial BP | 160 °C flash | not applicable / water content | none / 61 °C BP |
| Dielectric strength, 2.5 mm gap | 42 kV | 35 kV | not dielectric | 40 kV |
| Specific heat at 25 °C | 1.10 kJ/kg·K | 1.9 kJ/kg·K | 3.5 kJ/kg·K | 1.2 kJ/kg·K |