| HS Code | 341905 |
| Appearance | translucent |
| Hardness | 40 ± 2 Shore A |
| Density | 1.10–1.15 g/cm³ |
| Tensile Strength | ≥6.0 MPa |
| Tear Strength | ≥18 kN/m |
| Elongation At Break | ≥400% |
| Compression Set | ≤20% |
| Linear Shrinkage | ≤2.5% |
| Dielectric Strength | ≥20 kV/mm |
| Volume Resistivity | ≥1×10^14 Ω·cm |
| Dielectric Constant | ≤2.8 at 50 Hz |
| Dissipation Factor | ≤0.01 at 50 Hz |
| Tracking Resistance | ≥4.5 kV |
As an accredited Insulator Liquid Silicone Rubber RH-G601/40 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Insulator Liquid Silicone Rubber RH-G601/40 is supplied in 20 kg sealed plastic pails or drums for safe storage and transport. |
| Container Loading (20′ FCL) | 20′ FCL loaded with Insulator Liquid Silicone Rubber RH-G601/40 in sealed drums, palletized, securely strapped, and moisture-protected for sea shipment. |
| Shipping | Insulator Liquid Silicone Rubber RH-G601/40 is typically shipped in sealed pails or drums under dry, ambient conditions. Keep containers closed and protected from moisture, contamination, and extreme temperatures. Verify hazard classification, labeling, and transport requirements against the current SDS and local regulations before shipment. |
| Storage | Store Insulator Liquid Silicone Rubber RH-G601/40 in a cool, dry, well-ventilated area at 5–25 °C, away from direct sunlight, heat, moisture, and ignition sources. Keep containers tightly closed, upright, clearly labeled, and segregated from oxidizers, acids, alkalis, and foodstuffs. Do not freeze. Protect from physical damage. Observe shelf-life and first-in/first-out; consult the SDS and supplier instructions. |
| Shelf Life | Typical shelf life is 12 months from manufacture when stored unopened at ≤25°C, away from sunlight and moisture. |
The longest-established downstream insertion point for RH-G601/40 is the direct overmoulding of silicone sheds and sheath onto pultruded glass-fibre-reinforced epoxy rods for outdoor suspension and tension line insulators. The applicable compliance framework for the finished insulator is IEC 61109:2008 for composite suspension and tension insulators and IEC 62217:2012 for polymeric outdoor insulator design and test; long-term tracking and erosion resistance is evaluated according to IEC 60587:2007 Method 1 at 4.5 kV, with typical acceptance defined as no track beyond 25 mm and no erosion depth greater than 3 mm. The A and B components are metered at 1:1 by volume through a static mixer with 12–16 mixing elements; the metering units and feed lines are held at 20°C–25°C to suppress premature addition cure. The FRP core is preheated to 120°C–140°C, primed with a silane adhesion promoter, and inserted into a heated multicavity mould at 170°C–190°C. Injection pressure is normally limited to 80–150 bar; pressures above 150 bar have been observed in production trials to displace unsupported core lengths above 800 mm and to produce shed-wall thickness variation greater than ±0.3 mm. Cure time at the shed root is sized at 25–35 s per 10 mm of wall section, followed by demoulding and a forced-air post-cure of 4 h at 200°C to remove volatile siloxanes and stabilise hydrophobicity transfer. The terminal product class includes composite long rod suspension and tension insulators, jumper insulators, and railway catenary insulators covering system voltages from 12 kV AC to 800 kV DC. Silicone-rubber-to-FRP interfacial adhesion is verified by ISO 813:2019 with a typical minimum peel strength of 2.0 N/mm; lower values correlate with moisture ingress at the end-fitting seal under thermal-mechanical testing.
In separable connector and cable termination manufacturing, RH-G601/40 is injected as the external insulation body over pre-moulded silicone or EPDM stress control inserts. The governing standards are IEEE Std 48-2020 for test requirements of terminations and joints, IEC 60502-4:2010 for accessories for extruded cables from 6 kV to 30 kV, and HD 629.1 S2:2006 for the European compliance route. Metering is fixed at 1:1 by volume; because the mixed compound has a typical pot life of 24–48 h at 25°C but begins to build viscosity quickly in warm runner channels, cold-runner tooling above 30°C must be purged after downtime longer than 10 min. The second-stage shot is injected at 60–100 bar into a mould heated to 160°C–180°C; fill speed is set at 20–40 cm³/s for thin stress cone skirts to prevent flow marks at the deflector-to-insulation interface. Vulcanisation time is 45–90 s depending on wall thickness, and a post-cure of 2 h at 200°C is applied to reduce low-molecular-weight siloxanes and to stabilise interfacial pressure. The terminal parts are separable connectors, cold-shrink joint bodies, and outdoor terminations for single-core and three-core polymeric cables from 6/10 kV to 26/35 kV. Interface pressure is verified by partial discharge testing at 1.73 U₀; voids larger than 0.2 mm detected by X-ray or dye-penetrant inspection are cause for rejection. Mould venting at ≤40 mbar is required at the deflector skirt because insufficient venting appears as partial discharge failures during routine production testing.
Metal oxide varistor stack overmoulding for distribution-class surge arresters is carried out at a lower injection pressure than composite insulator moulding because the varistor blocks are brittle and are already aligned under axial compression. Under IEC 60099-4:2014 and IEEE C62.11-2020, the polymer housing must exhibit no voids at the block-to-silicone interface and must survive partial discharge and residual voltage tests. The addition ratio is 1:1 by volume, and mixed material is injected at 30–60 bar into a tool preheated to 150°C–170°C; injection speed is capped at 80 cm³/s because unbalanced flow across the ZnO stack can rotate the blocks and generate axial misalignment. Cure time in the tool is 60–120 s, followed by 4 h at 200°C in an air-circulating oven. When a primer is required for adhesion to end fittings, a silane coupling agent is applied and dried at 80°C for 30 min before moulding. The terminal product is a distribution-class polymer-housed surge arrester rated from 3 kV to 36 kV, with the silicone housing functioning as both dielectric insulation and weathershed. Processing in relative humidity above 60% RH requires substrate pre-drying to prevent moisture-induced pinholing at the block surface; amine-based release agents must be avoided because they poison the platinum catalyst.For transformer and wall bushing manufacture, RH-G601/40 can be injection-moulded directly onto filament-wound glass-fibre-reinforced epoxy cylinders to produce the weather-shed profile without post-machining or adhesive assembly. The governing standards are IEC 60137:2017 for bushings above 1 kV and IEEE C57.19.01-2017 for outdoor apparatus bushings; surface tracking and erosion resistance is additionally assessed by IEC 60587 under the end-product specification. The addition ratio is 1:1 by volume; because the cylinder functions as a rigid mandrel, injection pressure is set at 100–160 bar after the surface has been primed with a silane adhesion promoter and dried at 80°C for 30 min. The mould is heated to 170°C–190°C and the initial cure is 30–60 s per shed ring, with final post-cure 4 h at 190°C–200°C. Tooling design requires longitudinal parting lines and vacuum venting at the shed root because knit lines in this location increase the probability of leakage-current damage under wet pollution. The terminal parts are composite transformer bushings and wall bushings for oil-filled or dry-type transformers in the range of 24 kV to 245 kV; the silicone shed housing must pass a thermal-mechanical test sequence before routine production, and any void greater than 0.15 mm in the leakage-distance zone is rejected under X-ray inspection.
High-voltage busbar and connector overmoulding in electric-vehicle power distribution is an insertion point in which part thickness is dictated by creepage distance requirements rather than mechanical load. The applicable insulation coordination standard is IEC 60664-1:2020, and when a flammability class is specified, the final part geometry must be tested to UL 94 V-0 at 3.0 mm; published data for RH-G601/40 in this exact configuration may be limited, so lot-by-lot verification is required. The A:B ratio remains 1:1 by volume; injection is performed on a vertical C-frame LSR machine with clamping force from 60 t to 160 t, and the cold runner uses valve gating to prevent scorch during high-temperature operation. Mould temperature is set at 180°C–200°C and injection speed is kept at 20–50 cm³/s to fill copper busbar overmoulds with wall sections down to 0.5 mm without air traps. Post-cure is 2 h at 200°C before dielectric strength testing; terminal products are insulated busbar assemblies, connector bodies, and terminal covers for battery systems operating above 60 V DC. Adhesion to copper substrates is verified by ISO 813:2019 or the end-user specification; a minimum peel strength of 2.0 N/mm is commonly used, but the exact acceptance threshold is product-specific and must be validated on the final part geometry.| Downstream insertion point | Governing standard(s) | A:B addition ratio | Mould temperature range | Terminal component class |
|---|---|---|---|---|
| Composite long rod insulator overmoulding | IEC 61109:2008; IEC 62217:2012 | 1:1 by volume | 170–190°C | Suspension/tension line insulators, railway catenary insulators |
| Cable accessory stress control overmoulding | IEEE Std 48-2020; IEC 60502-4:2010; HD 629.1 S2:2006 | 1:1 by volume | 160–180°C | Separable connectors, cold-shrink joint bodies, outdoor terminations |
| Distribution arrester housing overmoulding | IEC 60099-4:2014; IEEE C62.11-2020 | 1:1 by volume | 150–170°C | Distribution-class polymer-housed surge arresters |
| Transformer bushing shed injection moulding | IEC 60137:2017; IEEE C57.19.01-2017 | 1:1 by volume | 170–190°C | Composite transformer and wall bushings |
| High-voltage busbar and connector overmoulding | IEC 60664-1:2020; UL 94 V-0 at 3.0 mm where specified | 1:1 by volume | 180–200°C | Insulated busbar assemblies, connector bodies, terminal covers |
| Property | Test method | Typical acceptance condition |
|---|---|---|
| Dielectric strength | IEC 60243-1 | 20 kV/mm minimum on a 2.0 mm plaque in transformer oil |
| Volume resistivity | IEC 62631-3-1 | 1×1014 Ω·cm minimum at 500 V DC |
| Tracking/erosion resistance | IEC 60587 Method 1 | 4.5 kV; no track > 25 mm; erosion < 3 mm |
| Tensile strength / elongation at break | ISO 37 | 6.0 MPa minimum; elongation 300% minimum |
| Tear strength | ISO 34-1 | 20 N/mm minimum, trouser specimen |
| Compression set | ISO 815-1 | 35% maximum after 22 h at 175°C |
Competitive Insulator Liquid Silicone Rubber RH-G601/40 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Insulator Liquid Silicone Rubber RH-G601/40 is a two-component, platinum-catalyzed addition-cure silicone elastomer supplied in a 1:1 mix ratio. The “40” designation corresponds to a nominal hardness of 40 Shore A after full cure. The grade is intended for high-voltage outdoor insulation components, including hollow-core composite insulator housings, cable termination stress cones, bushing covers, and surge-arrester jackets requiring resistance to tracking, corona discharge, and wet-surface leakage current. Unlike general-purpose liquid silicone rubber, the formulation includes a modified alumina trihydrate and fumed-silica package that balances low-shear pumpability against filled-system electrical stability. The uncured base is free of organotin compounds, and the addition-cure network releases no acetic acid or oxime by-products during crosslinking.
Because the hydrosilylation reaction proceeds without condensation by-products, cured parts exhibit lower volatile-siloxane carryover after the specified post-cure than condensation-cure RTV grades. The filler system increases the mixed viscosity relative to unfilled electronic-grade LSR, but it also raises comparative tracking index values and reduces surface tracking under contaminated wetting conditions. RH-G601/40 is formulated for closed-loop liquid injection molding and vacuum-assisted casting rather than hand-mixed open-mold processing, which distinguishes it from low-shear RTV silicones used in maintenance and field repair.
Table 1 lists representative first-party batch-certificate values for RH-G601/40. The values are measured on 2 mm sheets compression-molded at 120 °C for 10 min and post-cured at 200 °C for 4 h, unless otherwise noted. Electrical measurements are performed after 24 h recovery at 23 °C ± 2 °C and 50% ± 5% relative humidity.
| Property | Test method | Typical value | Measurement state |
|---|---|---|---|
| Density at 23 °C | ISO 1183-1:2019 | 1.12 g/cm³ | Post-cured sheet |
| Hardness | ISO 7619-1:2010 | 40 Shore A | Post-cured sheet |
| Mixed viscosity at 25 °C, 10 s⁻¹ | ISO 3219:2021 | 30,000 mPa·s | Uncured A+B blend |
| Tensile strength | ISO 37:2017 | 6.5 MPa | Post-cured sheet |
| Elongation at break | ISO 37:2017 | 420% | Post-cured sheet |
| Tear strength | ISO 34-1:2015 | 22 kN/m | Post-cured sheet |
| Compression set, 22 h at 177 °C | ISO 815-1:2019 | 18% | Post-cured sheet |
| Volume resistivity | IEC 62631-3-1:2016 | 1.0 × 10¹⁵ Ω·cm | Post-cured sheet |
| Dielectric strength | IEC 60243-1:2013 | 20 kV/mm | Post-cured sheet |
| Comparative tracking index | IEC 60112:2020 | >600 V | Post-cured sheet |
The compression set value is obtained after post-cure. Without post-cure, the value measured on 120 °C-cured sheets is typically 25%. The volume resistivity and dielectric strength values fall within the expected range for a heavily filled LSR; unfilled general-purpose LSR grades often show volume resistivity one decade higher, but their tracking resistance under IEC 60112:2020 is commonly below 300 V. The alumina hydrate filler shifts tracking performance upward but increases mixed viscosity and reduces low-frequency dielectric constant stability in very thin sections.
For closed-loop injection molding on 200 L drum feed systems, the A and B components are metered through a 30 mm static mixer at a ratio of 1:1 by volume. The mixed viscosity at low shear is approximately 30,000 mPa·s at 25 °C; at injection shear rates above 100 s⁻¹ the material exhibits pseudoplastic behavior and fills fully heated multi-cavity molds at cavity pressures between 0.2 MPa and 0.5 MPa. Shot-size control uses a screw or piston injector with a nozzle jacket held below 50 °C to prevent premature hydrosilylation in the barrel. Molds are heated to 120 °C to 180 °C, with a preferred surface set point of 140 °C for parts thicker than 5 mm. The lower set point avoids a thermal-modulus gradient that appears when alumina-trihydrate-filled LSR is cured above 180 °C and can produce surface scorch at vent locations. Production-floor measurements on 4-cavity surge-arrester housing tools indicate that mold-surface temperature deviation above ±5 °C across the cavities shifts local Type A durometer values by up to 3 points and can leave tacky under-cured sprues.
The practical pot life of mixed material is 72 h at 25 °C under sealed storage; no comparable ISO pot-life test exists, and the value is a production-floor observation. Lower temperatures extend handling time, but cooling below 5 °C increases apparent viscosity and can starve feed throats in unheated drum pumps. No post-mixing vacuum is required for thickness below 5 mm; for thicker sections, vacuum degassing is applied according to the humidity limits discussed below. LSR-specific check valves and static mixer elements should be used, and mixing equipment previously contaminated with sulfur-cured EPDM or amine-cured epoxy must be purged with xylene followed by isopropanol before production.
Although addition-cure LSR does not cure by moisture, absorbed water on the alumina hydrate filler can produce steam-induced porosity when the part cross-section exceeds 5 mm and mold temperature exceeds 130 °C. The failure mode appears as discrete spherical voids concentrated around metal inserts and gate regions rather than uniform foaming. When the ambient dew point exceeds 10 °C or relative humidity remains above 60% for more than 4 h, individual shots are degassed at −0.09 MPa for 2 min and the cavity is evacuated to −0.08 MPa before injection. Mold release agents based on silicone oil or soap are acceptable; amine-based release agents and sulfur-containing gloves are not used because platinum catalyst inhibition produces tacky, under-cured surfaces. The A and B components should be stored in unopened drums at 5 °C to 30 °C for a shelf life of 6 months; freezing does not crosslink the material but can cause filler sedimentation requiring low-shear rehomogenization.
A systematic comparison against peroxide-cure high-temperature vulcanized solid silicone, condensation-cure room-temperature vulcanized silicone, and hydrophobic epoxy clarifies the differences in processing and electrical behavior. Table 2 summarizes the primary distinctions. The addition-cure LSR enters the mold at ambient temperature and crosslinks by hydrosilylation rather than free-radical decomposition or moisture condensation. That removes post-mold bloom associated with peroxide residues and allows automated closed-loop metering, but it also imposes stricter contamination control. Condensation-cure RTV grades release acetic acid or oxime by-products and are typically processed in open molds at low shear, making their electrical tracking performance more sensitive to incomplete room-temperature cure and to entrained bubbles. Hydrophobic epoxy and rigid EPDM exhibit higher modulus and lower hydrophobicity recovery after water immersion; under dynamic bending at low strain, cured LSR retains elongation above 300%, whereas rigid epoxy systems may crack at the same deformation.
| Material | Cure mechanism and by-product | Processing equipment and window | Tracking behavior | Main operational constraint |
|---|---|---|---|---|
| RH-G601/40 addition-cure LSR | Hydrosilylation; no reaction by-product | LSR metering/injection; 120 °C/10 min; post-cure 200 °C/4 h | CTI >600 V under IEC 60112:2020 | Platinum-catalyst-compatible tooling |
| Peroxide-cure HTV solid silicone | Free-radical crosslinking; peroxide residues | Solid molding; 170–200 °C; post-cure required | CTI typically 400–600 V | Mold fouling; higher compression set |
| Condensation-cure RTV | Condensation; acetic acid or oxime by-products | Open-mold dispensing; moisture cure at 23 °C/50% RH; deep-section cure limited | CTI typically 300–500 V | Entrained air; variable electrical performance |
| Hydrophobic epoxy | Addition polymerization; exotherm | Pressure gelation; 80–120 °C | CTI typically 300–600 V | Rigid modulus; lower hydrophobicity recovery |
The comparative tracking index values in Table 2 are lot-dependent and may vary with filler surface treatment; the RH-G601/40 value in Table 1 is the release limit, not a guaranteed field-service rating for contaminated high-voltage environments. Direct published multilaboratory data for this specific grade under combined salt fog and inclined-plane aging are limited, so formal type testing should be performed on production-representative specimens.
Inclined-plane tracking evaluations for outdoor insulation are performed in accordance with IEC 60587:2007 using a contaminated liquid composed of ammonium chloride and nonionic wetting agent at a flow rate of 0.6 mL/min. The initial tracking voltage is commonly set at 4.5 kV for filled silicone elastomers. First-party type-test records for RH-G601/40 show erosion depth of less than 3 mm after 6 h at 4.5 kV when specimens are post-cured at 200 °C for 4 h; however, independent multilaboratory data for this exact grade are limited. For customer qualification, specimens should be molded on the same equipment and post-cured under the same thermal profile intended for production, because wet-arc performance is controlled by residual cyclosiloxane concentration, filler dispersion, and surface contamination. In production audits, parts showing localized erosion to the glass-reinforced epoxy core are normally associated with under-dispersion of the alumina hydrate filler or with mold contamination rather than with the base polymer.
Salt-fog chamber exposure under IEC 62217:2012, or the relevant ANSI/IEEE dynamic test, is generally used for housing material validation. The key parameter is not initial hydrophobicity but hydrophobicity recovery after corona and water immersion. Silicone elastomers are distinguished from epoxy and EPDM by the ability of low-molecular-weight siloxanes to migrate to the surface and restore a hydrophobic layer after wetting. For RH-G601/40, the post-cure cycle reduces free cyclosiloxane content; excessive post-cure can slow hydrophobicity recovery and reduce migration capacity, while insufficient post-cure leaves volatile siloxanes that can condense on conductor hardware and attract dust. The specified 200 °C/4 h profile represents the production trade-off between volatile removal and preservation of hydrophobicity recovery.
In hollow-core composite insulator manufacturing, metering of RH-G601/40 into a vacuum-assisted casting station or injection mold over a 60 mm pultruded glass-reinforced epoxy core is performed at cavity pressures between 0.2 MPa and 0.5 MPa. On a 1,500 kN clamp-force LSR injection machine, the material fills annular gaps of 5 mm to 20 mm without exceeding the core crush strength of the filament-wound substrate. Flash generation is controlled by parting-line design with 0.02 mm to 0.05 mm clearance; larger clearances permit air entrapment and surface porosity at the parting line. Bonding to the epoxy core generally requires a primer or an organofunctional silane adhesion promoter applied by automated brush or spray; unprimed adhesion is not reliable under thermal cycling from −40 °C to 80 °C because differential thermal expansion concentrates shear stress at the silicone-epoxy interface.
For cable termination and bushing cover molding, the grade is processed with the same closed-loop LSR equipment but with lower cavity pressures. The filled material resists wet-arc tracking better than unfilled electronic-grade LSR, while retaining the low-temperature flexibility required for cold-weather installation. Published data for severe desert or marine salt-spray service at this specific hardness is limited; application qualification should include the relevant IEC 60815 pollution class and IEEE C62.11 impulse tests on finished assemblies rather than on plaques alone.