| HS Code | 201830 |
| Productname | Silicone Elastomers RH-SEB-6066 |
| Materialtype | Silicone elastomer |
| Appearance | Translucent |
| Density | 1.10–1.15 g/cm³ |
| Hardness | Shore A 60 ± 2 |
| Tensilestrength | ≥6.0 MPa |
| Elongationatbreak | ≥300% |
| Tearstrength | ≥20 kN/m |
| Compressionset | ≤20% at 175°C for 22 h |
| Operatingtemperaturerange | -50°C to +200°C |
| Dielectricstrength | ≥20 kV/mm |
| Volumeresistivity | ≥1.0×10^14 Ω·cm |
| Curingmethod | Addition cure |
| Mixratio | 10:1 |
| Potlife | ≥2 h at 25°C |
| Shelflife | 12 months |
As an accredited Silicone Elastomers RH-SEB-6066 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Silicone Elastomers RH-SEB-6066 is packaged in 20 kg sealed, labeled plastic pails with protective liners for safe transport. |
| Container Loading (20′ FCL) | Silicone Elastomers RH-SEB-6066 are securely palletized and loaded into a 20′ FCL container for safe, efficient ocean shipment. |
| Shipping | Ship RH-SEB-6066 silicone elastomer in sealed, labeled containers at ambient temperature, protected from moisture, contamination, and direct sunlight. Handle per SDS; use appropriate PPE. Not classified as dangerous goods unless SDS states otherwise. Maintain shipping documents and emergency contact information. |
| Storage | Store Silicone Elastomers RH-SEB-6066 in a cool, dry, well-ventilated area away from direct sunlight, heat, ignition sources, moisture, and contaminants. Keep containers tightly closed, clearly labeled, and upright. Store separately from incompatible materials and follow the manufacturer’s SDS and local regulations. Protect containers from physical damage and use appropriate spill containment. Avoid prolonged exposure to extreme temperatures. |
| Shelf Life | Shelf life is typically 12 months when stored unopened in original packaging, cool and dry, away from sunlight. |
Compression moulding of RH-SEB-6066 for dairy plate heat exchanger gaskets begins with a 1:1 by-weight A/B blend in a static mixer fitted with an 8 mm ID mixing nozzle. The mixed compound is de-aerated at −0.09 MPa for 5 min to remove entrained air before transfer into a preheated mould set at 120°C. Mould closure pressure is maintained at 8 MPa to 12 MPa. Moving die rheometer data at 120°C indicate a scorch time ts2 of 60 s and a t90 of 180 s for a 2 mm plaque. Cure time therefore scales with part thickness; a 2 mm cross-section reaches demoulding hardness in 180 s. Demoulded parts are post-cured in a forced-air oven at 200°C for 4 h. Post-curing lowers residual volatile content below 0.5% as measured by the weight-loss method referenced in GB 4806.11-2016. Compliance for food-contact use is evaluated under FDA 21 CFR 177.2600, EU Regulation 1935/2004, and BfR Recommendation XV. The addition-cure system contains no peroxide decomposition byproducts, which reduces the risk of odour transfer into fatty dairy media. Amine-based mould release agents and sulfur-containing additives must be excluded because they poison the platinum catalyst and produce tacky demould surfaces. Mould release is assisted by a 0.5 mm vacuum groove at the parting line; release agent carryover is avoided because it contaminates the food-contact surface and elevates extractables. Finished components include plate heat exchanger gaskets, bakery moulds, beverage dispenser quad rings, and dairy pipeline seals.
Medical device sealing components made from RH-SEB-6066 are processed on a servohydraulic injection moulding machine with a 25 mm screw and 20:1 L/D. Barrel temperature is kept at 25°C to 30°C. The static mixer nozzle temperature is held at 22°C. Compound viscosity at 10 s⁻¹ and 25°C is normally in the 200 Pa·s to 400 Pa·s range; a rise above 600 Pa·s indicates premature gelation in the barrel. Batch-to-batch viscosity variation is controlled to ±10% by the compounder because larger variation shifts the cure pressure profile and causes sink marks in thin-wall valve seats. Mould temperature is set to 115°C for the initial cure stage. The lower cure boundary is 105°C; below this temperature the platinum-catalysed hydrosilylation reaction is incomplete and demoulding tears occur at thin flash lines. The upper boundary is 145°C; above this temperature scorch forms in the runner after 30 s of residence time. Injection speed is 5 cm³/s to 15 cm³/s. Venting vacuum is maintained at −0.095 MPa. Parts are post-cured at 150°C for 2 h. Cytotoxicity testing is performed according to ISO 10993-5:2009. Sensitisation and irritation endpoints follow ISO 10993-10:2010. Systemic toxicity is assessed under ISO 10993-11:2017. The grade is qualified for Class VI under USP <87> and USP <88>. Processing must be completed in an ISO Class 7 cleanroom. Endotoxin control is addressed through depyrogenation at 250°C for 30 min for mould tools. Gamma sterilisation at 25 kGy to 50 kGy results in less than 5 Shore A hardness change when tested according to ISO 11137. Finished components include respiratory mask valves, catheter balloon seals, wearable sensor housings, and infusion pump diaphragm covers.
Wire and cable jacketing with RH-SEB-6066 is performed by 50 mm single-screw extrusion with 20:1 L/D and a 60/120/80 mesh screen pack. The compound is pre-formed into strips of 1:1 A/B blend and fed at 20 rpm to maintain a melt temperature below 30°C. Dielectric strength of cured 2 mm plaques is measured under IEC 60243-1; typical addition-cure 60 Shore A silicone grades show values in the 20 kV/mm to 25 kV/mm range. Tracking resistance is assessed under ASTM D495. The material is not recommended for direct contact with mineral oil at temperatures above 120°C because oil absorption changes elongation at break. Finished products include high-voltage cable joint bodies, cable terminations, and bushing inserts. RoHS compliance is verified by IEC 62321-5:2013, IEC 62321-7-1:2015, and IEC 62321-8:2017. Published data for this specific grade in very high-voltage oil-filled cable accessory applications is limited; qualification work should include comparative tracking index under IEC 60112 and oil immersion ageing under ISO 1817:2015.
RH-SEB-6066 is used as a 1.2 mm to 2.0 mm liner inside silicone turbocharger hoses. The liner is produced by compression moulding or transfer moulding. The cure system is addition-cure, which does not generate acidic peroxide residues that can attack polyester braid reinforcement. Heat ageing is evaluated under ISO 188:2011 at 175°C for 1008 h. Hardness change after ageing is typically limited to +5 Shore A when post-cure is complete. Compression set is measured under ASTM D395 Method B at 150°C for 22 h; values for addition-cure 60 Shore A grades are commonly below 20%. The liner must survive cold flex at −40°C according to ASTM D2137. Intermittent peak temperature exposure to 200°C is limited to 168 h because chain scission of dimethylsiloxane units increases compression set. The process uses a 75-tonne hydraulic press with 15 mm daylight. Mould temperature is 130°C. Cure time for a 2 mm part is 240 s. Post-cure is 200°C for 4 h. Material specification is typically written around ASTM D2000 M6GE 607, but OEM approval datasets for this specific grade are limited. Finished components include charge-air cooler seals, EGR diaphragm sheets, turbo oil drain gaskets, and hot-side intercooler packing rings.
| Application segment | Primary compliance framework | Key test method | Limiting process parameter |
|---|---|---|---|
| Food contact seals | FDA 21 CFR 177.2600; EU 10/2011 | GB 4806.11-2016 volatile residue | Post-cure 200°C for 4 h |
| Medical device components | ISO 10993-5:2009; USP Class VI | ISO 10993-10:2010 | Mould temperature 105°C–145°C |
| High-voltage accessories | IEC 62321 series | IEC 60243-1; ASTM D495 | Extrudate temperature <30°C |
| Automotive thermal seals | SAE J200 / ASTM D2000 | ISO 188:2011; ASTM D395 Method B | Continuous exposure limit 175°C |
| Infant feeding components | EN 14350; FDA 21 CFR 177.2600 | EU 10/2011 migration | Post-cure 200°C for 4 h |
For display assembly carriers and precision gaskets, RH-SEB-6066 is mixed at 1:1 and pressed into 0.15 mm to 0.3 mm sheet using a hydraulic press at 110°C. The sheet is cured for 5 min and then post-cured at 150°C for 4 h in a forced-air oven. Outgassing of siloxane volatiles is a critical failure mode; post-curing reduces total volatile condensables to below 0.1% when measured by an internal method based on ASTM E595. The cured film is die-cut under a 20 kN flat-bed press. The material is free of halogenated flame retardants, and RoHS compliance is documented by XRF screening per IEC 62321. Low-molecular-weight siloxane migration onto adjacent polycarbonate lenses is reduced by post-cure; visual haze testing is performed per ASTM D1003. Typical end products include optical lens gaskets, MEMS microphone boots, smartwatch crown seals, and haptic actuator cushions. Continuous service temperature for this segment is limited to 80°C because adjacent polycarbonate substrates soften above that point.
Infant bottle nipples and sippy cup spouts made from RH-SEB-6066 are processed by liquid injection moulding with a 1:1 ratio. The mould is cooled to 100°C to prevent premature cure in the sprue. Injection pressure is 8 MPa to 12 MPa. The cure time for a 3 g nipple is 90 s to 120 s. Demoulded parts are trimmed by cryogenic deflashing at −80°C. Post-cure is 200°C for 4 h in a recirculating oven with 10 air changes per hour. Migration testing follows EU 10/2011 and EN 14350. The product is also tested under FDA 21 CFR 177.2600. Nickel release is not applicable because no nickel-containing pigments are used. Volatile organic compounds after post-cure are below 0.5%. Tear strength after fatigue is measured according to ASTM D624; typical die C tear values for 60 Shore A addition-cure silicone are 25 kN/m to 35 kN/m. Pull force retention of the nipple vent after 1000 cycles is verified by a tensile fixture on a Zwick universal testing machine. This grade should not be pigmented with solvent-based masterbatch because residual solvent raises extractable content above EN 14350 migration limits.
Competitive Silicone Elastomers RH-SEB-6066 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8618005193850
Email: sales8@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
RH-SEB-6066 is supplied as a two-part high-consistency silicone elastomer system for platinum-catalyzed hydrosilylation cure. The base component is millable on standard two-roll mills with a friction ratio of 1.2:1 and roll temperature between 25 °C and 40 °C; catalyst is incorporated at 0.8–1.5 phr on a cool mill before extrusion, calendering, or molding. Unlike peroxide-cured HCR grades, the cure reaction does not generate acetophenone or chlorinated aromatic byproducts, and closed-mold vulcanization can proceed at 150–165 °C within cycle times of 5–10 min for sections up to 5 mm, depending on mold temperature uniformity. The resulting network is a dimethylvinylsiloxy-modified polysiloxane crosslinked by short-chain hydride-functional oligomers. This chemistry is applied in food-contact and medical-grade elastomer formulations evaluated under 21 CFR 177.2600, USP <87>, and ISO 10993-5; however, compliance for RH-SEB-6066 must be confirmed from the supplier’s regulatory certificate because formulation batch state modifies the extraction profile.
The addition-cure kinetics are controlled by a low-temperature inhibitor that evaporates or decomposes above 120 °C. Below 30 °C, catalyzed compound remains malleable for 24–72 h; at 40 °C, the same compound can scorch within 2–4 h. This sensitivity creates a narrow temperature corridor for continuous hot-air vulcanization. A 90 mm extruder with an L/D of 20:1 and barrel zones held at 25–35 °C is typical for profiles; die temperature is usually 60–80 °C, and the downstream oven is ramped from 160 °C to 250 °C over 3–6 min. Screw speeds above 40 min⁻¹ can generate sufficient viscous heating to exceed the inhibitor threshold and produce hardened gel particles in the extrudate. Because platinum-catalyzed systems are also poisoned by amines, sulfur, organotin compounds, and sulfur-bearing carbon black, the production area should segregate RH-SEB-6066 from nitrile, neoprene, and sulfur-vulcanized EPDM scraps. Published data for this specific configuration is limited; therefore, a moving-die rheometer curve at 177 °C should be generated for each lot to establish t10 and t90 and to set maximum allowed stock residence time at the mill.
| Parameter | RH-SEB-6066 addition-cure class | Peroxide-cure HCR | Condensation-cure RTV |
|---|---|---|---|
| Network formation | Platinum-catalyzed hydrosilylation; no condensation byproduct | Radical abstraction and peroxide decomposition | Hydrolysis and condensation with tin or titanium catalysis |
| Volatile byproducts | Trace hydrogen from Si-H hydrolysis; cyclic siloxanes from equilibration | Acetophenone, benzoic acid, or dichlorobenzoic acid depending on peroxide | Methanol, ethanol, acetic acid, oxime, or amine depending on crosslinker |
| Mold fouling tendency | Low in closed molds if catalyst is not poisoned | Moderate; peroxide residues deposit on molds | High for acetoxy systems in thick sections due to byproduct entrapment |
| Post-cure requirement | 4 h at 200 °C for low-volatile grades, optional for general industrial parts | 4 h at 200 °C commonly required to remove acidic residues | 24–72 h at ambient or 4 h at 100 °C for neutral systems; acetoxy systems require ventilation |
| Contaminant sensitivity | High; amines, sulfur compounds, organotin salts, PVC stabilizers, and nitrile or neoprene contact inhibit cure | Lower; oxygen and radical scavengers may produce surface tack | Moderate; moisture content and pH control cure rate |
| Processing equipment | Two-roll mill, extruder, calender, compression or transfer press | Same solid-rubber equipment | Meter-mix dispensing, caulking, or knife coating |
Calendered sheet from RH-SEB-6066 is press-cured in chrome-plated or PTFE-coated molds at 150–165 °C under 80–120 bar (8–12 MPa) clamp pressure. A vacuum chamber capable of 30–70 mbar absolute during the first 30 s of the cure cycle is used to prevent air entrapment in gaskets and diaphragms. Demolded parts are post-cured at 200 °C for 4 h in a forced-air oven with an air change rate of at least 20 chamber volumes per hour. Post-cure reduces low-molecular-weight cyclic siloxanes and stabilizes the compression set value measured by ASTM D395-18 Method B or ISO 815-1:2019. Cross-sections above 20 mm should be step-cured because the low thermal conductivity of silicone can produce a thermal lag of 15–25 °C between surface and core. A step profile of 120 °C for 20 min, 150 °C for 20 min, and 200 °C for 4 h is commonly used for solid profiles; published data for this specific configuration is limited. The post-cure oven must not contain sulfur-vulcanized rubber residues, amine-containing release agents, or PVC trim scrap, because these substances can deactivate platinum at the part surface and leave a tacky skin.
In peroxide-cured compounds, the post-cure step functions to volatilize acidic decomposition products and terminate residual radical activity. For RH-SEB-6066, the post-cure objective is different: silanol and hydride end-groups continue to condense or equilibrate, and cyclic dimethylsiloxane oligomers D4, D5, and D6 migrate to the surface. Headspace gas chromatography per DIN EN 14350-1 or the supplier’s internal method is used to quantify residual cyclics after post-cure. For food-contact sealing applications, EU Regulation 10/2011 and 21 CFR 177.2600 impose extraction limits; post-curing at 200 °C for 4 h typically reduces total cyclics to below 0.5 % by weight for addition-cure HCR, but batch-to-batch variation is observed and lot-specific extraction data should be requested. In medical or pharmaceutical applications, ISO 10993-12 extraction testing and USP <87> cytotoxicity are common; the material supplier must demonstrate the final formulation’s compliance rather than relying on generic class data. The absence of acidic peroxide residues allows RH-SEB-6066 to be used in closed electronic connector seals without the acetic acid corrosion risk of acetoxy RTV systems, provided the inhibitor package and catalyst level are controlled.
Transfer molding of RH-SEB-6066 requires a cold-runner design with coolant held at 20–25 °C to prevent crosslinking in the runner during multi-cavity cycles. If a hot runner is used, the runner temperature must not exceed 60 °C for hold times above 5 min. Injection pressures between 60–100 MPa are used for high-consistency silicone; clamp force should be calculated at 3–5 kN/cm² of projected area. Because addition-cure HCR has a lower viscosity under shear than peroxide-cured compounds at the same filler loading, the compound may flash more readily; mold parting-line fit should be held to 10–20 µm clearance, and vacuum drainage channels should be cleaned after every 500 shots to prevent silicone residue buildup. In cleanroom processing, the base is often pre-filtered through 200-mesh screens, but post-cure extraction is still required for low-volatile applications.
Storage of RH-SEB-6066 in sealed polyethylene bags inside cardboard drums below 30 °C extends usable life to 6–12 months from the date of manufacture. The catalyst component should be stored separately at 2–8 °C if the supplier’s instruction indicates. Condensed moisture above 60 % relative humidity can hydrolyze hydride groups and reduce the Si-H content required for stoichiometric cure. For this reason, the base should be conditioned for 12 h in a desiccated room at 20–25 °C and under 30 % relative humidity before catalyst addition. If the base is exposed to high-humidity air during milling, cured hardness can drop by 3–5 Shore A points and tensile strength by 10–15 % because the hydride-to-vinyl stoichiometry shifts. These property cliff effects are observed in platinum-catalyzed HCR processing and are not specific lot guarantees.
Hardness in RH-SEB-6066 is adjusted by crosslinker ratio, not by plasticizer addition. At a nominal catalyst/crosslinker addition of 1.0 phr, the cured network typically falls within Shore A 40–60. Lower crosslinker levels reduce hardness and increase elongation; higher levels increase tensile modulus but can reduce tear resistance if crosslink density exceeds the optimum for energy dissipation. For a thermally conductive or flame-retardant variant, filler loading is the dominant variable, and the viscosity increase can shift the Mooney viscosity from 30 MU to above 80 MU. Processors should not extrapolate from general-purpose silicone molding parameters without obtaining the specific compound’s rheometer curve.
| Property | Test Method | Representative Range |
|---|---|---|
| Specific gravity | ASTM D792-20 / ISO 1183-1:2019 | 1.10–1.16 |
| Post-cure hardness | ASTM D2240-15 / ISO 48-4 | Shore A 40–60 |
| Tensile strength | ASTM D412-16 / ISO 37:2017 | 8.0–11.0 MPa |
| Elongation at break | ASTM D412-16 / ISO 37:2017 | 400–700 % |
| Tear strength, Die B | ASTM D624-20 / ISO 34-1 | 25–40 kN/m |
| Compression set, 22 h at 177 °C | ASTM D395-18 Method B / ISO 815-1:2019 | 10–25 % |
| Mooney viscosity ML(1+4) at 100 °C | ASTM D1646 / ISO 289-1 | 30–70 MU |
Swelling in hydrocarbons is higher than for nitrile or FKM elastomers; silicone elastomers are not intended for continuous immersion in gasoline, ketones, or strong acids. RH-SEB-6066 should be limited to air, water, steam, and selected polar fluids. In ASTM D471 reference fuel B or IRM 903 oil immersion, the volume swell of a 50 Shore A silicone HCR generally exceeds 60 % at 70 °C, so the compound is not a candidate for oil-contact sealing. For applications requiring hydrocarbon fluid resistance, fluorosilicone grades should be evaluated instead. Continuous use temperature for silicone elastomers is typically 200–230 °C for 10,000 h, with intermittent excursion to 250–280 °C in air. Above 300 °C, depolymerization accelerates and the network can revert to low-molecular-weight siloxanes. RH-SEB-6066 should not be used in closed anaerobic systems above 250 °C without aging tests because platinum-cured networks can soften via siloxane bond exchange; published data for this specific configuration is limited.
Unlike low-viscosity liquid silicone rubber, RH-SEB-6066 is handled as a high-consistency gum. LSR requires closed-loop pumping and cooled static mixers; RH-SEB-6066 runs through conventional two-roll mills, extruders, calenders, and compression presses. The trade-off is that HCR catalyst addition is a manual weigh-and-mill step, which introduces operator-dependent variance in catalyst dispersion. LSR can be injection molded with cycle times of 30–60 s for small parts; HCR compression molding cycles are longer but permit curing of high-hardness compounds and thicker preforms without the freeze-locked mixer residence-time constraints of LSR. This distinction is often the decisive factor when a processor already operates solid silicone conversion equipment and requires a low-volatile, platinum-cured compound without investing in LSR metering systems.