Silicone Elastomers RH-SEB-9060L

    • Product Name: Silicone Elastomers RH-SEB-9060L
    • Factroy Site: No. 168, Jinhai Middle Road, Binhai New Area, Southern Ningbo, Ninghai County, Ningbo City, Zhejiang Province.
    • Price Inquiry: sales8@bouling-chem.com
    • Manufacturer: Zhejiang Runhe Chemical New Material Co., Ltd.
    • CONTACT NOW
    VTB
    Specifications
    HS Code 728871
    Appearance translucent
    Cure Type addition-cure/platinum-catalyzed
    Mixing Ratio 1:1 by weight
    Volume Resistivity Ohm Cm 1.0E+15
    Operating Temperature Range C -60 to 200
    Cure Condition 24 h at 25 °C or 2 h at 80 °C

    As an accredited Silicone Elastomers RH-SEB-9060L factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing RH-SEB-9060L silicone elastomer is packaged in 20 kg sealed plastic pails or fiber drums for safe storage and transport.
    Container Loading (20′ FCL) A 20′ FCL container is loaded with Silicone Elastomers RH-SEB-9060L, securely palletized, stowed, and braced for safe ocean shipment.
    Shipping Ship Silicone Elastomers RH-SEB-9060L in original, sealed containers, kept cool, dry, and protected from moisture, heat, and contamination. Follow the SDS and all applicable transport regulations, and ensure shipping labels and documentation are complete and accurate.
    Storage Store in a cool, dry, well-ventilated area away from direct sunlight, heat sources, and ignition. Keep original containers tightly closed, properly labeled, and protected from moisture, dust, and contaminants. Avoid contact with strong acids, bases, and oxidizing agents. Maintain stable temperature, do not stack excessively, and follow first-in, first-out stock rotation. Observe local regulations and the manufacturer’s SDS.
    Shelf Life Silicone Elastomers RH-SEB-9060L: shelf life is typically 12 months from manufacture when stored unopened in original packaging under cool, dry conditions.
    Application of Silicone Elastomers RH-SEB-9060L

    What Limits Post-Cure Shrinkage in Infusion Pump Diaphragm Molding?

    RH-SEB-9060L is handled as a two-part platinum-catalyzed addition-cure silicone elastomer. The metering unit must hold the A/B ratio specified in the supplier certificate of analysis within ±2%. Forced-feed plunger pumps and static mixers are required. Shot size variation is typically controlled below 0.5% of nominal. The material shear-thins at injection shear rates above 100 s⁻¹. Molding is performed in an ISO 14644-1 Class 7 cleanroom when the finished diaphragm enters a sterile disposal path. The raw feed containers are not opened in uncontrolled areas because silicone picks up airborne hydrocarbon contamination.

    For infusion pump diaphragms with wall thickness from 0.25 mm to 0.80 mm, mold cavity pressure is commonly held between 20 MPa and 40 MPa. Injection speed is set at 8–25 cm³/s according to runner diameter and gate geometry. The mold temperature window normally ranges from 120°C to 160°C. Cure time is calculated at 30–60 s per millimeter of nominal wall section. A closed-loop electric LSR injection molding machine with clamp force control is used to prevent flash at parting lines. Vacuum is pulled to at least -0.8 bar before injection to remove trapped air from thin diaphragm features.

    Post-cure is performed in a vented forced-air oven at 200°C for 4 h. This step removes volatile cyclic siloxanes and completes network formation. Linear shrinkage after post-cure for this elastomer class is usually 2.0–3.5%. Mold dimensions must include shrink compensation of 1.5–4.0% because uneven cooling can produce out-of-tolerance diaphragm thickness. Thickness gradients above 0.02 mm across the sealing bead can cause pump flow rate drift. The post-cure oven must be validated for uniform airflow across every batch tray.

    Tensile strength is evaluated according to ASTM D412 on die-cut slabs. Elongation at break is evaluated according to ASTM D412 or DIN 53504. Tear strength is evaluated according to ASTM D624 Die B. Typical addition-cure LSR at 60 Shore A hardness shows tensile strength of 6–10 MPa, elongation of 300–700%, and tear strength of 15–35 kN/m. The supplier technical data sheet for RH-SEB-9060L must be checked for exact batch data because these class-range values are not a substitute for lot-specific release testing.

    Biocompatibility for infusion pump diaphragms requires cytotoxicity per ISO 10993-5, skin sensitization per ISO 10993-10, and hemolysis per ISO 10993-4 when blood contact is possible. Raw material traceability under ISO 13485 is required. Published data for RH-SEB-9060L in long-term implanted configurations is limited; this material is not presented as an implantable-grade elastomer without batch-specific validation and design-specific risk assessment.

    For injection-molded infant feeding valves and sippy-cup spouts, food contact status under FDA 21 CFR 177.2600 and EU Regulation EC 1935/2004 governs raw material selection. A platinum-catalyzed addition-cure silicone elastomer is preferred over peroxide-cured rubber because post-cure residuals can be reduced below organoleptic detection thresholds in thin-walled parts. The A/B ratio for these parts is normally 1:1, but the supplier certificate of analysis must confirm the exact ratio for RH-SEB-9060L. Metering deviation outside ±1.5% can produce soft zones and sink marks in valve lips thinner than 0.50 mm.

    Mold temperature for thin-wall valves is set at 130–170°C. Cure time is 20–45 s for wall sections from 0.40 mm to 1.20 mm. Cavity vacuum below -0.8 bar prevents air entrapment at the sealing lip. After demolding, valves are post-cured 4 h at 204°C in a positive-pressure oven. Residual cyclic siloxane content is commonly controlled below 0.5 wt% by headspace GC-MS according to internal protocols aligned with EN 14350-2. Dimensional tolerances for valve lips are held to ±0.03 mm. Cavity pressure sensors monitor peak pressure below 50 MPa to prevent flash at the lip edge.

    Extractables testing for food-contact silicones follows FDA 21 CFR 177.2600 and migration testing per EN 1186-1. The overall migration limit is 10 mg/dm² for food contact. Heavy metal release is measured by ICP-MS against the limits set in FDA 21 CFR 177.2600. Finished valves are assembled into polypropylene caps and subjected to leak tests at 0.5 bar for 2 s. A functional seal must survive repeated opening and closing without visible tearing or compression set above 20% when tested at 70°C for 22 h.

    Automotive Connector Seal Compression Set After 168 h at 150°C

    Compression set is the controlling property for underhood connector seals. A specimen is compressed to 25% of original thickness and aged at 150°C for 168 h according to ASTM D395 Method B or ISO 815-1. The specimen is released and measured after 30 min at room temperature. For addition-cure LSR of 50–70 Shore A, compression set typically falls between 15% and 30% under these conditions. A value above 40% often indicates incomplete cure, incorrect A/B ratio, or insufficient post-cure. Connector seal compounds that cannot stay below 35% after this aging are generally rejected for long-term underhood use.

    Connector seals are molded by LSR injection molding machines with dynamic static mixers. The metering pump must hold 20–25°C on the A and B feed lines to avoid premature cure in the mixer. The cold runner nozzle gate diameter is 0.30–0.80 mm. Injection speed is set at 5–20 cm³/s. Mold temperature is held at 140–180°C. Cure time is 30–90 s depending on seal cross-section. Vacuum is pulled to -0.9 bar. Mold vent depth is maintained at 0.005–0.010 mm to allow air escape without flash formation. Flash above 0.03 mm on a connector seal interferes with terminal harness assembly.

    Fluid resistance tests for automotive connectors include immersion in engine oil, diesel, and urea solution. Volume change after 70 h at 150°C in IRM 903 oil typically remains below 10% for medium-hardness addition-cure LSR when tested according to ISO 1817. Hardness shift is measured per ASTM D2240. Thermal aging at 175°C for 1000 h per ISO 188 is used to estimate service life. Retention of tensile strength above 70% and elongation above 60% is typical after this aging. No surface tack or cracking is permitted.

    The finished article is installed in sealed connector housings and tested to IP67 according to IEC 60529 after thermal shock from -40°C to 125°C. The seal must retain its groove position during vibration testing per SAE J1455. Any deformation set above 25% after vibration indicates insufficient crosslink density or low tear resistance at the inner lip. Production-scale LSR molding lines monitor shot weight every 30 min and record cavity pressure curves for traceability.

    When seal cross-sections drop below 0.30 mm in outdoor LED driver enclosures, control of contact contamination by cyclic siloxanes becomes the defining requirement. RH-SEB-9060L in a low-volatile formulation is processed with the same addition-cure metering discipline as medical molding, but the acceptance tests shift to outgassing and surface resistivity. A perimeter gasket is molded at 130–160°C with cure time of 20–50 s. Post-cure typically runs 4 h at 200°C to reduce low-molecular-weight siloxane content. Under-cured parts are not shipped because residual cyclic dimethylsiloxane oligomers can migrate to nearby optical surfaces and electrical contacts.

    Electrical enclosure gaskets are tested for compression set at 100°C for 22 h per ASTM D395. The compression set value after this shorter aging usually remains below 15% for 60 Shore A material. Ingress protection is confirmed by IEC 60529 IP65 or IP67 tests. The gasket must survive -40°C cold start without loss of sealing force. Tensile and elongation are not the primary release criteria in this application because compression set and sealing force retention better predict field performance.

    Limitation: avoid placing under-cured silicone elastomer in direct contact with unsealed electromechanical relay contacts. Cyclic dimethylsiloxane oligomers can migrate to contact surfaces and form insulating silicon dioxide under arc conditions, increasing contact resistance. If the application includes open relays or slip rings, a silicone-free elastomer or a sealed relay chamber is required. Contact resistance drift is measured per ASTM B539. Finished parts are used as perimeter gaskets for IP-rated power supplies, sensor housings, and outdoor lighting fixtures where long-term environmental exposure is expected.

    When Peristaltic Pump Tubing Requires USP Class VI and ISO 10993-5 Simultaneously

    Platinum-cured silicone tubing in biopharmaceutical transfer lines is specified under both USP Class VI and ISO 10993-5 because it contacts drug product and patient-associated fluids. RH-SEB-9060L, if supplied in a durometer suitable for extrusion, must be mixed at the ratio defined in the batch certificate. For continuous extrusion, a silicone-specific single-screw extruder with L/D 12:1–20:1 and a cooled feed throat is used. The screw temperature profile is set from 20°C at the feed zone to 60°C at the die. The vulcanization oven after the die operates at 250–450°C for 2–10 min depending on wall thickness. Line speed and oven residence time must be recorded for every production reel.

    Post-cure at 200°C for 4 h is mandatory for low extractables. Extractables testing is conducted according to ISO 10993-12 with ethanol/water and isopropanol extraction. The resulting extracts are analyzed by GC-MS and ICP-MS. Tubing must demonstrate no cytotoxicity per ISO 10993-5 and no sensitization per ISO 10993-10. USP Class VI testing requires systemic injection, intracutaneous, and implantation endpoints per USP <88>. The table below summarizes the standard matrix for this application.

    End-use requirementStandardTypical test condition
    CytotoxicityISO 10993-5L929 mouse fibroblast MEM extraction, 24 h at 37°C
    SensitizationISO 10993-10LLNA or guinea pig maximization test
    Systemic injectionUSP Class VINaCl extraction, 70 h at 121°C
    IntracutaneousUSP Class VINaCl and cottonseed oil extracts
    EndotoxinUSP <85>LAL chromogenic method

    Mechanical requirements for peristaltic pump tubing include tensile strength above 8 MPa per ASTM D412 and elongation above 500%. Tear strength per ASTM D624 Die B should exceed 20 kN/m. The inner bore surface roughness is controlled below Ra 0.4 µm to reduce protein fouling and microbial adhesion. Flex fatigue life is tested under cyclic compression at 0.5 Hz and -0.8 bar suction pressure. Tubing is expected to withstand 10⁶ cycles without splitting or inner wall delamination. Hardness changes after fatigue are measured per ASTM D2240 and must remain within ±5 Shore A of the initial value.

    Cleaning and sterilization compatibility includes autoclave at 121°C for 30 min for 5–20 cycles and gamma irradiation up to 50 kGy. Hardness and tensile retention after sterilization are measured per ASTM D2240 and ASTM D412. Silicone tubing should not be autoclaved in the presence of strong acids or amine-based additives because amines accelerate depolymerization of the siloxane backbone. This limitation is critical when the same transfer line is used with alkaline cleaning agents or amine-stabilized pharmaceutical buffers.

    Cold-Runner Tooling Geometry Controls Flash Formation in Micromolded Cosmetic Valve Seals

    The limiting process variable in micromolded cosmetic valve seals is gate vestige height. For airless pump dispenser valves in cosmetic packaging, the sealing lip must close without leakage at back pressures above 0.3 MPa. RH-SEB-9060L is molded in cold-runner tooling with valve gate diameters from 0.30 mm to 0.60 mm. The mold is held at 140–170°C. Injection pressure is limited to 30–60 MPa. Cure time is set at 15–40 s depending on gate size and wall section. Gate vestige is controlled below 0.05 mm to avoid user-noticeable surface defects on the outer housing.

    Flash formation is controlled by mold venting at a depth of 0.003–0.008 mm. Vacuum below -0.9 bar is applied before injection. The parting line is maintained at ±0.005 mm flatness across the cavity insert. Flash above 0.02 mm on the sealing lip causes cosmetic product leakage and is rejected. Cavity pressure sensors monitor the end-of-fill curve. A pressure drop above 10% before cure completion is treated as a process deviation because it indicates premature gate freeze or material starvation.

    Regulatory compliance for cosmetic contact is confirmed under EU Regulation EC 1223/2009. REACH SVHC content is controlled below 0.1% w/w. Finished seals are tested for color stability after 72 h immersion in ethanol/water mixtures at 40°C. Hardness is measured per ASTM D2240. Compression set after 24 h at 70°C is held below 18%. The finished part is assembled into airless pump closures and leak-tested at 0.5 bar for 1 min without pressure decay. These seals serve in cosmetic pump dispensers for creams, serums, and lotions where repeated actuation must not degrade sealing force.

    Free Quote

    Competitive Silicone Elastomers RH-SEB-9060L prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618005193850 or mail to sales8@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618005193850

    Email: sales8@bouling-chem.com

    Inquiry

    Get Free Quote of Zhejiang Runhe Chemical New Material Co., Ltd.

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    RH-SEB-9060L is a silicone elastomer grade identified by the model prefix RH, the series code SEB, and the suffix 9060L. No independent decoding of the suffix is asserted; batch-specific values for hardness, tensile strength, elongation at break, tear strength, density, and compression set must be taken from the supplier’s certificate of analysis and verified against ISO 9001 lot documentation. The product should be processed only after the cure system is confirmed from the manufacturer’s technical datasheet. In the absence of manufacturer-specific numerical data, the following sections describe the test methods, process variables, and class-level comparisons that apply to silicone elastomers of this type.

    Because silicone elastomers differ by cure chemistry, filler type, and inhibitor package, substituting RH-SEB-9060L into an existing mold or mixing line requires re-qualification. A change from one silicone grade to another can alter rheology, cure rate, mold fouling, and volatile profile even when durometer values are identical. The product model is therefore reviewed here in terms of processing class, standard test methodology, equipment conditions, and known incompatibility boundaries rather than as a fixed list of numerical property claims.

    What Processing Category Does RH-SEB-9060L Occupy?

    The product belongs to the class of addition-cure silicone elastomers if the supplier’s cure schedule specifies platinum-catalyzed crosslinking at elevated mold temperature. Addition-cure silicones cure by hydrosilylation between vinyl-functional siloxane polymers and silicon-hydride crosslinkers, typically without releasing condensation byproducts. This distinguishes them from condensation-cure RTV grades, which liberate alcohol, acetic acid, or oxime species during cure. In practice, the absence of cure byproducts reduces void formation in thick sections and permits closed-loop injection molding. However, the product’s classification as a liquid silicone rubber or high-consistency rubber must be confirmed from the supplier’s published rheological data. The trailing L in the grade designation may indicate a low-viscosity variant, but published data for this specific configuration is limited; no viscosity range is assigned here without manufacturer confirmation.

    Addition-cure liquid silicone rubber is commonly metered and mixed as two components, then injected into a heated mold. The processing form differs from peroxide-cured high-consistency rubber, which is supplied as a gum and requires mastication before flow. For comparative ranking, viscosity is measured on a cone-plate or parallel-plate rheometer under ISO 3219 or ASTM D4287. The numerical viscosity limit for RH-SEB-9060L is grade-specific and is not reproduced here without batch data.

    Cure classCatalyst/initiatorTypical processing formByproductCommon limitation
    Peroxide-cured HCROrganic peroxideHigh-consistency gumPeroxide decomposition residuesPost-cure required; volatile byproducts
    Platinum-catalyzed addition LSRPlatinum complexLiquid, closed-loop injection moldingNone from cure reactionCatalyst poisoning by amines, sulfur, organotin
    Condensation RTVTin or titanium catalystPourable or pasteAlcohol, acetic acid, oximeShrinkage; slower deep-section cure

    For incoming quality control, a silicone elastomer is tested according to a fixed set of standardized methods. Hardness is reported as Shore A under ASTM D2240 or ISO 48-4; tensile strength and ultimate elongation are determined under ASTM D412 or ISO 37; tear resistance is measured under ASTM D624 or ISO 34-1. Specific gravity is frequently reported under ASTM D792 or ISO 1183-1. Compression set values are generated under ASTM D395 Method B or ISO 815-1, often after 22 h at 175 °C; however, the exact time and temperature for RH-SEB-9060L must be extracted from the supplier’s lot certificate. Viscosity, thixotropy, and pot life are measured on a cone-plate or parallel-plate rheometer; ISO 3219 and ASTM D4287 cover rotational viscometric methods but not product-specific limits.

    PropertyStandard methodTypical reporting unit
    HardnessASTM D2240 / ISO 48-4Shore A
    Tensile strengthASTM D412 / ISO 37MPa
    Elongation at breakASTM D412 / ISO 37%
    Tear strengthASTM D624 / ISO 34-1kN/m
    DensityASTM D792 / ISO 1183-1g/cm³
    Compression setASTM D395 Method B / ISO 815-1%

    No product-specific values are reproduced above because lot-dependent variation makes tabulated fixed values unreliable. The supplier’s certificate of analysis is the only valid source for numerical specifications.

    Platinum-Catalyzed Hydrosilylation Governs the Cure Profile

    For addition-cure grades, crosslinking proceeds through hydrosilylation between vinyl-functional polydimethylsiloxane chains and silicon-hydride functional crosslinkers. The reaction is strongly temperature-dependent; mold temperature increases are a primary lever to reduce cycle time within the supplier’s recommended range. Typical liquid silicone rubber processing uses mold temperatures from 120 °C to 180 °C, but RH-SEB-9060L may possess a narrower cure window if filler type or inhibitor content has been adjusted. Cure inhibition occurs when the platinum catalyst contacts amines, organotin compounds, sulfur-containing species, or certain unsaturated organic additives. Therefore, production lines that handle condensation-cure or sulfur-vulcanized rubber must be cleaned before material changeover. The cure profile is reported as time to 90 % maximum torque on a moving die rheometer according to ISO 6502 or ASTM D5289; comparative ranking of RH-SEB-9060L against other addition-cure silicones requires the same instrument geometry and temperature protocol.

    At high mold temperatures, the competing rates of injection filling and crosslinking determine whether short shots, knit lines, or scorch defects occur. The injection speed must be high enough to fill thin sections before cure advances, but excessive shear can generate viscous heating and local cure in the static mixer or nozzle. Production-scale liquid silicone rubber injection machines use cooled barrels and water-jacketed static mixers to maintain material temperature below 25 °C; mold temperature is controlled by cartridge heating and thermocouple feedback with a tolerance of ±2 °C across the cavity surface. For multi-cavity tools, cavity-to-cavity temperature variation above 5 °C can produce inconsistent cure states at demolding, affecting tear strength and compression set. Thus, RH-SEB-9060L should be qualified on the target tool with cavity pressure sensors, not by coupon molding alone.

    For production-scale processing of addition-cure liquid silicone rubber, a closed-loop metering and mixing unit is used to combine Part A and Part B in a fixed ratio, often 1:1 by volume or weight depending on grade architecture. The mixed compound is conveyed through a static mixer and injected into a heated mold with a defined clamp force. In injection molding, mold temperature, injection speed, and holding pressure are controlled to prevent flash, air entrapment, and scorch. Barrel cooling is maintained between 18 °C and 25 °C to prevent premature cure before the shot enters the cavity. Mold release is minimized or avoided because external release agents can interfere with the addition-cure surface finish. Degassing by vacuum is recommended before molding for filled grades or those with high viscosity; the threshold is grade-specific and no specific rheology value for RH-SEB-9060L is asserted here. In extrusion or coating operations, high-shear dispersion may require temperature-controlled single-screw or twin-screw configurations; published data for this specific configuration is limited, and the equipment manufacturer’s torque limits should be observed.

    When Peroxide-Cured HCR Is Replaced by RH-SEB-9060L in Closed-Loop Injection Molding

    Substitution of a peroxide-cured high-consistency rubber with an addition-cure liquid silicone elastomer alters the molding sequence. Peroxide-cured HCR requires extended compression or transfer molding cycles, a preform, and a post-cure step to decompose residual peroxide byproducts. Addition-cure liquid silicone rubber is pumped, mixed, and injected into a hot mold, reducing cycle time and allowing automated demolding. The difference in consistency is measured as viscosity; liquid grades flow under low shear, whereas HCR requires mastication and softening before flow. RH-SEB-9060L should be compared with HCR on the basis of ISO 6502 cure curves, ASTM D2240 hardness, and ASTM D624 tear resistance rather than by visual consistency alone. The absence of peroxide decomposition byproducts lowers volatile content in many applications, but specific outgassing limits for RH-SEB-9060L must be taken from supplier test data. In clean-room molding, contamination control includes filtering the liquid components through fine-mesh filters and verifying platinum catalyst compatibility with the mold steel and surface treatments.

    RH-SEB-9060L, if it follows the addition-cure platinum catalyst system, is incompatible with contact surfaces containing tin-catalyzed silicone residues, sulfur-vulcanized rubber dust, amine-cured epoxy, and certain grades of nitrile or latex gloves. Catalyst poisoning can prevent surface cure or increase tackiness at the part surface even when bulk cure appears complete. Storage life and working time are temperature-sensitive; unmixed components should be kept sealed in the original containers at the temperature stated in the supplier’s safety data sheet, typically below 30 °C. Mixed material should be processed within the stated pot life at ambient temperature, which for addition-cure systems is usually extended at 20–25 °C but shortens markedly above 40 °C. Pre-drying of fillers or substrates may be required if the relative humidity exceeds 60 %; water can interfere with adhesion and trapped moisture can cause void defects. These operational boundaries are standard for addition-cure silicone processing; the exact limits for RH-SEB-9060L require confirmation from the manufacturer’s technical datasheet.

    Post-Cure Volatile Content and Outgassing Criteria

    Low-molecular-weight siloxane species can remain in silicone elastomers after molding and migrate to the surface over time. In applications involving electrical contacts, optical lenses, or medical devices, residual volatile content is quantified by weight loss after post-curing, often according to ASTM E595. A post-cure cycle of 4 h at 200 °C is used for many addition-cure silicone elastomers to reduce volatile content, but the necessary time and temperature for RH-SEB-9060L are grade-specific. For food-contact or medical use, compliance is established through FDA 21 CFR 177.2600, ISO 10993-5, or ISO 10993-10 as applicable, not by inference from visual clarity or Shore hardness. The comparison between RH-SEB-9060L and other addition-cure grades with identical durometer values may still differ in volatile profile because of variations in low-molecular-weight siloxane content, filler type, and inhibitor package. Therefore, the product cannot be substituted into an existing mold or device without re-qualification against the relevant extraction, biocompatibility, and outgassing specification.